Impact of plan parameters on the dosimetric accuracy of volumetric modulated arc therapy.

Masi L, Doro R, Favuzza V, Cipressi S, Livi L.

Abstract

PurposeTo evaluate the effect of plan parameters on volumetric modulated arc therapy (VMAT) dosimetric accuracy, together with the possibility of scoring plan complexity.Methods142 clinical VMAT plans initially optimized using a 4° control point (CP) separation were evaluated. All plans were delivered by a 6 MV Linac to a biplanar diode array for patient-specific quality assurance (QA). Local Γ index analysis (3%, 3 mm and 2%, 2 mm) enabled the comparison between delivered and calculated dose. The following parameters were considered for each plan: average leaf travel (LT), modulation complexity score applied to VMAT (MCSv), MU value, and a multiplicative combination of LT and MCSv (LTMCS). Pearson's correlation analysis was performed between Γ passing rates and each parameter. The effects of CP angular separation on VMAT dosimetric accuracy were also analyzed by focusing on plans with high LT values. Forty out of 142 plans with LT above 350 mm were further optimized using a finer angle spacing (3° or 2°) and Γ analysis was performed. The average Γ passing rates obtained at 4° and at 3°∕2° sampling were compared. A further correlation analysis between all parameters and the Γ pass-rates was performed on 142 plans, but including the newly optimized 40 plans (CP every 3° or 2°) in place of the old ones (CP every 4°).ResultsA moderate significant (p ConclusionsAt 4° CP sampling, LT, MCSv, and LTMCS were found to be significantly correlated with VMAT dosimetric accuracy, expressed as Γ pass-rates. These parameters were found to be possible candidates for scoring plan complexity using threshold values. A finer CP separation (3°∕2°) led to a significant increase in dosimetric accuracy for plans with high leaf travel values, and to a decrease in correlation between LT and Γ passing rates. These results indicated that the influence of LT on VMAT dosimetric accuracy can be controlled by reducing CP separation. CP spacing for all plans requiring large leaf motion should not exceed 3°. The reported data were integrated to optimize our clinical workflow for plan creation, optimization, selection among rival plans, and patient-specific QA of VMAT treatments.

Identifiers

Relevant Saxsons product

Related in the same topics