MAX 4000 Plus Reference Electrometer
0.001 pA
min current
500 nA
max current
0.1%
repeatability
< 1 fA
leakage
Reference
grade

Authorised Indian Distributor

Saxsons Group

New Delhi, India · Since 1997

SX
Radiotherapy RT-010 AERB Importable Reference Grade

MAX 4000 Plus Reference Electrometer

Versatile and accurate. One of the most widely used reference electrometers in radiotherapy — covering absolute dosimetry, patient dosimetry, SRS and all QA protocols from daily output to annual calibration.

Key Features

  • Reference-grade for all radiation therapy dosimetry applications
  • Exceptional current range: 0.001 pA to 500.00 nA
  • Charge range: 0.01 pC to 999,999 nC
  • 0.1% repeatability — exceeds TRS-398 and TG-51 requirements
  • Leakage current less than 1 fA — lowest in class
View all features

All Features

  • Reference-grade for all radiation therapy dosimetry applications
  • Exceptional current range: 0.001 pA to 500.00 nA
  • Charge range: 0.01 pC to 999,999 nC
  • 0.1% repeatability — exceeds TRS-398 and TG-51 requirements
  • Leakage current less than 1 fA — lowest in class
  • Digital filter technology eliminates RF and environmental noise
  • Redesigned display for improved readability and clarity
  • MAX COMM™ software for dose/dose-rate control and data logging
  • Remote electrometer operation via MAX COMM interface
  • Chamber and detector management built-in
  • Stereotactic and small-field dosimetry compatible
  • Suitable for absolute, relative and patient dosimetry

Technical Specifications

Current range 0.001 pA to 500.00 nA
Charge range 0.01 pC to 999,999 nC
Repeatability 0.1%
Leakage current < 1 fA
Noise reduction Digital filter technology
Display Redesigned high-visibility display
Software MAX COMM™ — dose, dose-rate, logging, remote
Remote operation Yes — via MAX COMM
Chamber management Built-in detector database
Applications Absolute, relative, patient dosimetry; SRS; daily/monthly/annual QA
Standards TRS-398, TG-51, TG-142 compatible

Applications

One electrometer — the full dosimetry spectrum

Absolute Reference Dosimetry

TRS-398 and TG-51 reference dosimetry with Farmer-type chambers. 0.001 pA minimum current resolves even the smallest ionisation signals.

Annual & Monthly Machine QA

Accurate output measurements for TG-142 annual and monthly QA. Remote operation via MAX COMM frees the physicist from the vault during irradiation.

Patient Dosimetry

In-vivo and point-dose patient dosimetry with compatible diode and IC detectors. Data logging to MAX COMM for audit trail.

SRS / Stereotactic Applications

Measures very small ionisation currents (< 1 pA) required for small-field SRS chamber characterisation without saturation or noise.

Daily Output Monitoring

Fast digitisation with digital filter for clean, repeatable daily output measurements. Chamber correction factors stored in device memory.

Electron Beam Dosimetry

Full charge integration mode for pulsed electron beam measurements. Compatible with parallel-plate chambers for electron reference dosimetry.

Why MAX 4000 Plus?

0.001 pA
Dynamic range

From the smallest small-field SRS measurement to the largest calibration beam, the MAX 4000 Plus covers nine decades of current without switching external hardware.

< 1 fA
Leakage floor

Sub-femtoampere leakage is the lowest specification available in a clinical electrometer. Measurements near detection threshold are not polluted by instrument leakage.

30+ yrs
Proven worldwide

Three decades of precision electrometer design. The MAX 4000 Plus is in routine clinical use at thousands of radiotherapy centres worldwide.

Available through Saxsons Group

The reference electrometer for Indian radiotherapy

Contact Saxsons Group for pricing, AERB import documentation, calibration traceability and installation support.