FDG Synthesis Cassette
Single-use automated synthesis cassette for FDG radiopharmaceutical production. Compatible with major commercially available synthesis modules.
Complete catalogue across Nuclear Medicine, Radiotherapy, Oncosurgery, Dosimetry and Cyclotron. AERB-compliant supply to 1,000+ hospitals across India.
Cyclotron-grade [18O]H2O for F-18 target loading via the 18O(p,n)18F reaction. Isotopic enrichment 98–99 % atom O-18, chemical purity > 99.99 %, conductivity < 3.0 µS/cm, sterile + pyrogen-free (< 0.25 EU/mL), pH 6.0–8.0. Sealed crimp-cap glass vials with chlorobutyl septum, sterilised prior to filling. Per-batch certificate of analysis covering isotopic, chemical, sterility and ionic-impurity testing. Cold-chain delivery across India.
Single-use automated synthesis cassette for FDG radiopharmaceutical production. Compatible with major commercially available synthesis modules.

Tema Sinergie FLEX GMP Grade A shielded dispensing isolator for cyclotron radiopharmacy. 100 mm Pb India configuration. F-18 PET tracer dispensing with Lu-177 theranostic capability. Optional µ DDS-A automatic dose drawing. Designed against EU GMP Annex 3 + 1 + 11 and AERB cyclotron-facility requirements.
Complete reagent kit for radiopharmaceutical synthesis. Includes precursor vials and QC reagents. Full documentation and release certificate supplied.

Tema Sinergie SYNT shielded synthesis hot cell for cyclotron F-18 PET tracer production. 100 mm Pb India configuration. Hosts automatic synthesis modules behind GMP Class B ventilation with ISO 10648:2 air-tightness and AISI 316L stainless inner finish. Pairs with FLEX dispensing.

Tema Sinergie CRP Compact and CRP Compact plus automated dispensing module. Drops into any shielded laminar-flow hot cell (typically the FLEX). Open + closed vial dispensing with under-1% volume deviation. 100 units installed worldwide. EU GMP Annex 1 compliant. Primary use in India: F-18 PET tracer unit-dose dispensing.

Tema Sinergie µ DDS-A plug-and-play automatic dose drawing module. Drops into any laminar-flow hot cell with a dose calibrator. Shielded-syringe output with built-in manual-backup mode. 274 units installed worldwide. India primary use: backup F-18 dispenser to the CRP / FLEX workflow.

Tema Sinergie WGHS — radioactive off-gas disposal system for cyclotron synthesis cells. Detects radioactive gases, isolates the host hot cell, stores gas in tanks pending decay, releases safely after decay, records per-cycle data. Facility-level utility. Pairs with the SYNT synthesis cell.

Automated F-18 radiosynthesizer with two independent reaction-vessel sets — two [18F]FDG batches from one operator setup. Basic hydrolysis < 28 min, acid hydrolysis < 22 min, radiochemical purity > 98 %, guaranteed RCY 65–85 %. Multi-tracer chemistry: FDG, FMISO, FLT, FCh and other nucleophilic [18F] compounds. Compact 42 × 50 × 48 cm footprint, fits a SYNT-class synthesis hot cell.
High-volume air sampler for radioactive aerosol + radioiodine sampling. Universal AC motor, vacuum-gauge flow monitoring, cast-aluminium filter holder. Total-Filtration Iodine Air (TFIA) configuration: 4-inch paper filter for particulates + dual back-to-back 2-1/2-inch activated charcoal cartridges for I-131 / I-125 capture with collection-efficiency cross-check. ANSI N13.1 / ISO 2889 stack-monitoring fit, ANSI N42.18 hot-lab fit, IAEA Safety Reports radioiodine air-sampling fit. Dual 115 V / 230 V variants.

Ambient neutron dose equivalent rate H*(10) monitor for cyclotron facilities, PET centres, particle accelerator workplaces, neutron calibration laboratories and spent-fuel storage areas. Two adjustable alarm levels; autonomous local operation or full integration into the site RMS via RS-485 + Ethernet. IP-rated for indoor and outdoor deployment.

Gas-less smart-scintillation hand-foot-clothing contamination monitor for alpha, beta and gamma emitting radionuclides. Two hand + two foot detectors with optional detachable hand probe. Two-step hand measurement (palms + backs), multi-language voice prompts, Ethernet LAN standard. The exit-point safety device for nuclear-medicine hot-lab, cyclotron and theranostic-centre egress.

Central radiation-monitoring-system server + software application. Aggregates area gamma, neutron, contamination, stack and air monitors into one console with single-channel and multi-channel tables, alarm management and archived-value trending. Modular architecture scales from a small PET centre to a multi-vault cyclotron-and-therapy facility. LAN + RS-485 connectivity.

Gaseous effluent air monitor for facilities producing, processing and using positron-emitting radionuclides. NaI(Tl) GD-53 gamma detector installed inside or beside the ventilation duct with optional collimator. Baseline variant (1K MCA, region-of-interest) and spectroscopic variant (1K-8K MCA with peak analysis). For cyclotron and PET centre stack release monitoring.

Compact local touchscreen display unit for radiation-monitoring systems. Connects up to four detectors directly via Ethernet or RS-485 and forwards the cluster to the host RMS via Ethernet. Integrated audible / visual alarms, 5,000-value local archive (adjustable storage period from 10 s), ruggedised variant available for harsher install locations.

Compact gamma dose-equivalent-rate area monitor with integrated backlit display and Ethernet interface (no RS-485-to-Ethernet bridge needed). Two adjustable alarm levels, optical + audible indication, ≥180-day local data archive, relay outputs. Standalone autonomous operation OR integrated into the RMS server. IP-rated for indoor + outdoor deployment.
High-performance liquid chromatography with online radioactivity detector for radiopharmaceutical QC. Dual-detector configuration. 21 CFR Part 11 compliant.
Long-lived germanium-68/gallium-68 calibration source for PET scanner normalisation and dose calibrator verification. NIST-traceable certificate.
NaI and HPGe gamma spectroscopy systems for radionuclide identification and activity measurement. Used in hotlab QA and waste characterisation.

Reusable beryllium-oxide (BeO) optically stimulated luminescent dosimeter for in-vivo radiotherapy. Validated 2025 (Kowalski Duke, Davis UVA) — equal-or-superior to the discontinued Landauer nanoDot in TBI, TSET, electrons and out-of-field measurements.
Molybdenum-99/Technetium-99m generator for daily SPECT imaging. EU-GMP certified cold-kit generator available in 5-dose and 10-dose configurations. AERB import licensed.
No-carrier-added Lutetium-177 paired with PSMA-617 (vipivotide tetraxetan) for VISION-protocol theranostic therapy in PSMA-positive metastatic castration-resistant prostate cancer (mCRPC). Specific activity ≥3,000 GBq/mg, radionuclidic purity ≥99.9 %. Cold-chain delivery across India.
No-carrier-added Lutetium-177 paired with DOTATATE peptide for peptide receptor radionuclide therapy (PRRT) in SSTR2-positive neuroendocrine tumours. NETTER-1 / NETTER-2 protocol — n.c.a. starting material, ≥99.9 % radionuclidic purity, AERB-importable, cold-chain delivery across India.

Pressurised-ionisation-chamber dose calibrator with 5-second measurement cycle. Displays in MBq or mCi. Operator-set calibration factors per isotope and per source geometry — no pre-programmed factors. AERB compliant.
High-activity I-131 capsules for thyroid cancer ablation and hyperthyroidism therapy. Available in calibrated activity levels per prescription.

Online radioactivity flow detector for radio-HPLC radiopharmaceutical QC. Swap-in scintillator probes across SPECT and PET isotope energies (Tc-99m, F-18, Ga-68, Lu-177, Cu-64). Configurable lead-castle background shielding, adjustable flow-cell volumes, standard HPLC tower integration. Eur.Ph. / USP <823> %RCP release on the HPLC chromatogram, 21 CFR Part 11 audit trail.

Multi-channel gamma analyser for radionuclide identification and radionuclidic-purity testing. NaI(Tl) standard chassis or HPGe high-resolution chassis (MUCHA Nova HR). Automatic energy calibration on startup, comprehensive nuclide library auto-ID, touchscreen-driven hot-lab workflow. SQL audit-trail database, 21 CFR Part 11 compliant. Mo-99 / Ge-68 / Lu-177m breakthrough checks per Eur.Ph. monographs.

Cobalt-57 flood source for gamma camera uniformity QA. NEMA NU-1-2007 compliant. Available in round and rectangular formats.

NIST-traceable sealed sources for dose calibrator constancy and accuracy testing. Available as Co-57/Co-60/Cs-137/Ba-133 set.

Ge-68/Ga-68 line sources for PET and PET-CT 2D/3D normalization. Double-layer stainless steel, argon-welded. ±5% uniformity.

Tema Sinergie KARL100 Class A multi-tracer dispenser + patient injection system. Seven isotopes (F-18, C-11, Ga-68, Cu-64, Lu-177, Y-90, Ra-223). Portable 1 kg shielded mini-injectors travel from hot lab to injection room. 200 units installed worldwide.

Saxsons own-brand all-in-one shielded hot lab workstation. Integrates a dose calibrator, L bench, sharps container shield, and tungsten vial shield dose dispenser (PET; lead variants for SPECT and I-131). Stainless steel countertop with 0.5″ spill-proof lip. Two lockable doors, four sliding drawers. Self-shielded — no additional room shielding required for the workstation. Designed and manufactured in India by Saxsons Healthcare Pvt. Ltd.

Sealed radioactive reference sources in the standard EVial polyethylene-vial geometry. Multiple isotopes (Co-57, Co-60, Cs-137, Ba-133 and others) and activity levels selectable per QA application. NIST-traceable certificates. AERB sealed-source import licensed. Compatible with all dose calibrators using the standard EVial geometry.

NIST-traceable QA reference sources for dose calibrators, well counters and PET system QC. Co-57, Co-60, Cs-137 and Ba-133 available individually or as a four-isotope set. Spans 81 keV (Ba-133) to 1.332 MeV (Co-60). AERB sealed-source import licensed.

Saxsons own-brand AERB-compliant return and disposal logistics for end-of-life sealed sources. Covers flood sources, line sources, QA reference sources, EVial sealed sources and sealed therapy sources supplied through Saxsons. Includes decommissioning documentation, decay-store coordination, AERB transport paperwork, India-wide pickup, and final disposal certificate. Operated in India by Saxsons Healthcare Pvt. Ltd.
No-carrier-added Lutetium-177 (n.c.a. ¹⁷⁷LuCl₃ in 0.04 M HCl) — the theranostic starting material. Specific activity ≥3,000 GBq/mg at calibration, radionuclidic purity ≥99.9 %, negligible Lu-177m. cGMP / ICH-Q7, supported by FDA Drug Master File. Drop-in compatible with PSMA-617, DOTATATE and FAPI labelling. Cold-chain delivery across India.
No-carrier-added Lutetium-177 paired with FAPI-46 (or FAPI-04) for investigational fibroblast-activation-protein-targeted radionuclide therapy in pancreatic adenocarcinoma, soft-tissue sarcoma and FAP-positive solid tumours. Hospital-ethics-committee-approved and CDSCO investigational-use coverage required. Saxsons supplies the radionuclide leg + AERB import paperwork.

Handheld pancake-GM survey meter with halogen-quenched tube + thin mica window (1.4–2.0 mg/cm²) — alpha, beta, gamma and X-ray detection from 10 keV up. Sensitivity 3,340 CPM per mR/hr (Cs-137 reference). Dose-rate range 0.01 to 1,000 µSv/hr. USB data logging via Windows Observer software; optional Bluetooth to Android. ~800-hour AA battery life. NIST-traceable calibration.

Handheld Geiger counter with halogen-quenched pancake GM tube (45 mm effective diameter, 1.5–2.0 mg/cm² mica window). Alpha · beta · gamma · X-ray detection. Sensitivity 3,500 CPM per mR/hr (Cs-137). Dose-rate range 0.01 to 1,100 µSv/hr. Multi-mode display (µSv/hr · mR/hr · CPM · CPS). ≥3,500-hour single-AA battery life. 3.5 mm output for PC / data-logger.
Electronic personal dosimeter (EPD) measuring personal dose equivalent Hp(10) — gamma + X-ray real-time cumulative dose AND instantaneous dose-rate readout on the device LCD. Configurable audible / visual / vibration alarms on both cumulative dose and dose rate. Solid-state silicon-detector technology. Multi-month battery life. IR / USB download to PC for per-operator dose-history retention. The active companion to the passive TLD / OSL badge.

Single-detector radio thin-layer chromatography scanner for radiopharmaceutical purity QC. NaI(Tl) scintillation detector spanning the full nuclear-medicine isotope range. Motorised low-noise scan stage (50–100 mm strip travel). USB / Ethernet to QC software running on a Windows workstation — peak detection, Eur.Ph. / USP <823> %RCP calculation, 21 CFR Part 11 audit trail. Daily radiochemical-purity release for Tc-99m, F-18, Ga-68, Lu-177 and I-131 batches.

Dual-position radio-TLC + basic gamma-spectrometry instrument. Two detector positions — one for the scanning radio-TLC head, one for a fixed gamma-spectrometry probe — driven from a single QC software session. Radiochemical purity and radionuclidic identity on the same instrument, the same batch record, the same release. Eur.Ph. / USP <823> %RCP + nuclide-identity peak match. AERB-licensed hot-lab QC.

Compact radio-TLC scanner — reduced footprint for space-constrained radiopharmacy benches and theranostic hot labs. Same NaI(Tl) detection chain as the standard radio-TLC scanner; smaller chassis fits a 600 mm bench depth. Motorised scan stage with low-noise drive. USB / Ethernet to QC software (Eur.Ph. / USP <823> %RCP, 21 CFR Part 11). The right radio-TLC instrument for a hot lab that doesn't have the bench space for a full-size scanner.

Saxsons own-brand lead-lined fume hood family — fully configurable hot-lab workstation manufactured in an ISO 9001 / ISO 13485 approved plant in India. Lead-shielded enclosure (3 mm / 5 mm / 6 mm / 10 mm / 12 mm options) with stainless-steel-lined work zone (SS202 or SS304), counter-weighted clear acrylic sliding door, fluorescent / LED work-area lamp and CE-marked motor driving an AMCA-certified centrifugal fan through an active-carbon (and optional pre-filter + HEPA + UV) filtration train. Standard 51×25×55-inch frame; small (41×23×51), mid (54×27×57, 56×30×52, 58×34×55), large (58×38×73) and compact (39×26×27) variants. Optional accessories — hot-wire anemometer, negative-pressure sensor with 10-inch PLC touch panel, body shield with lead-glass window, dose-calibrator ionisation-chamber mount, gamma-probe mount, lead-ring shielding, generator + waste compartments — configured per site SOP. Minimum face velocity 0.5 m/s per AERB guidelines. Designed and manufactured in India by Saxsons Healthcare Pvt. Ltd.

Saxsons own-brand tungsten syringe shield family for PET radiopharmaceutical dispensing — F-18, Ga-68, Lu-177 (theranostic), Cu-64. 9 mm tungsten-alloy shielding with engraved lead-glass viewing window on the side. Sizes 1 cc, 2 cc, 3 cc, 5 cc and 10 cc. 2 / 3 / 5 cc variants ship with a turn-lock mechanism that secures the syringe with a single twist; 10 cc variants use a thumb-screw lock. Colour-coded end caps mark the syringe size — Red = 2 cc, Black = 3 cc, Blue = 5 cc — so the operator picks the right shield at glance-speed on the dispensing bench. Two-millimetre tungsten low-profile and bottom-draw-shield (BDS) variants available. ISO 9001 / ISO 13485 manufactured. Designed and manufactured in India by Saxsons Healthcare Pvt. Ltd.

Saxsons own-brand lead-lined syringe shield family for SPECT radiopharmaceutical dispensing — Tc-99m kits, I-123 / I-131 (with higher shielding tiers), Ga-67, In-111, Tl-201. 3 mm lead standard for routine 140 keV Tc-99m work; 6 mm and 9 mm tiers for I-131 and higher-energy emitters; SS-202 or SS-304 outer finish. Lead-glass viewing window with calibration scale on the side. Sizes 1 cc, 2 cc, 3 cc, 5 cc and 10 cc. Thumb-screw lock holds the syringe in place. ISO 9001 / ISO 13485 manufactured. Designed and manufactured in India by Saxsons Healthcare Pvt. Ltd.

Saxsons own-brand lead vial shield family for the radiopharmacy hot lab — covers SPECT dispensing (6 mm Pb), I-131 dispensing (12 mm Pb), PET dispensing (30 / 50 mm Pb with magnetic top-cap closure), Lu-177 theranostic dispensing, transportation (40 mm lead pot), storage (9.5 / 10 mm Pb) and beta-gamma hybrid (Pb + Perspex / Acrylic) work. SS-202 outer chassis with SS or lead inner; optional lead-glass viewing window with engraved calibration scale. Vial capacity range 15 / 30 / 32 / 68 cc. Closure styles: slide lock, thread turn lock, pin turn lock, thread + magnetic top cap, thread + rotating cap. Manufactured in an ISO 9001 / ISO 13485 approved plant. Designed and manufactured in India by Saxsons Healthcare Pvt. Ltd.

Saxsons own-brand tungsten-alloy vial shield family for high-activity PET and high-energy SPECT dispensing — the higher-density alternative to lead at 511 keV F-18 / Ga-68 / Cu-64 and Lu-177 theranostic dispensing. Three-tier configuration: SPECT (5 mm tungsten, slide lock, 30 cc vial), PET 3-part with magnetic top cap (20 mm tungsten, body + lid + top cap, 15 cc), high-activity PET 2-part (30 mm tungsten, separate cap and base, 30 cc). Smaller chassis than the equivalent lead shield at the same attenuation; lower-fatigue dispensing across high-throughput PET shifts. Manufactured in an ISO 9001 / ISO 13485 approved plant. Designed and manufactured in India by Saxsons Healthcare Pvt. Ltd.

Saxsons own-brand PET L-Bench family for 511 keV radiopharmaceutical dispensing — FDG, Ga-68, Cu-64, Lu-177 theranostic prep. Lead-shielding tiers 50 mm and 60 mm. Sizes 14″×14″×24″ compact through 24″×24″×24″ standard 2′×2′×2′. Lead-glass viewing window 8″×8″×4″ with standard and premium tier options. MS painted or SS 304 outer finishes. Optional base-lead and 50 mm side-shielding packs. ISO 9001 / ISO 13485 manufactured in India by Saxsons Healthcare Pvt. Ltd.

Saxsons own-brand SPECT L-Bench family for Tc-99m (140 keV) routine dispensing, I-131 (364 keV) thyroid-iodine work and β-γ mixed-emission isotopes (Y-90, P-32, Sr-89). Lead-shielding tiers 6 mm (SPECT), 12 mm (I-131 routine), 25 mm (I-131 boosted), plus a 6 mm Pb + 6 mm Perspex β-γ hybrid build. Lead-glass viewing window 12″×16″×8 mm (wide) or 12.5″×8″×8 mm (compact). MS painted, SS 202 or SS 304 outer finishes. Optional bottom-side-lead. ISO 9001 / ISO 13485 manufactured in India by Saxsons Healthcare Pvt. Ltd.

Saxsons own-brand multi-syringe shielded carriers for safe transport of dispensed unit-dose syringes between hot lab and injection room. Lead tiers 3 mm (SPECT) / 6 mm (PET routine) / 6+12 mm lateral (high-activity PET) / 12 mm premium. β-γ hybrid (Pb + Perspex/acrylic) for Y-90, P-32, Sr-89 and Lu-177 theranostic work. SS 202 / SS 304 outer finishes. Long-handle design for ALARA distance. ISO 9001 / ISO 13485 manufactured in India.

Saxsons own-brand lead-shielded sharps containers for radioactive needle/syringe disposal. Tiers 3 mm (SPECT) / 6 mm (I-131) / 12 mm (routine PET) / 25 mm (high-activity PET / Lu-177). Magnetic top-cap closure, hinged lid for sharps removal, integrated lock. Cylindrical / rectangular / square form factors. SS 202 / SS 304 / MS painted outer. ISO 9001 / ISO 13485 manufactured in India.

Saxsons own-brand foot-operated waste bins for radioactive solid-waste containment. Lead shielding on ALL sides including lid. Tiers 3 / 6 / 12 / 25 mm. Inner volumes 14-17 L. Foot-pedal hands-free lid. Wheel-mounted 12 mm Pb option. SS 202 / SS 304 outer. ISO 9001 / ISO 13485 manufactured in India.

Saxsons own-brand decay drums for half-life-based hold of radioactive solid waste before final biomedical-waste disposal. Lead tiers 3 / 6 / 12 / 13 (actuator) / 25 mm. Chassis 321×381 mm compact to 530×1100 mm 100 L high-volume. MS painted / SS 202 outer. ISO 9001 / ISO 13485 manufactured in India.

Saxsons own-brand lead shielding rings for dose-calibrator chambers, well-counter detectors and multi-channel-analyser MUCHA-class breakthrough testing. Tiers 30 / 45 / 50 / 58 mm Pb. Internal diameters 80-176 mm matched to standard vendor chambers. Stack heights 200-660 mm. Saxsons Lead Castle variants with handle. ISO 9001 / ISO 13485 manufactured in India.

Saxsons own-brand mobile lead-lined barriers for hot-lab bench, injection-room and therapy-suite shielding. Tiers 6 / 12 / 25 / 30 / 60 mm Pb. Height-adjustable hydraulic-jack variants with integrated bench tray (60 mm Pb). Four lead-glass viewing-window formats. Injector cart and Moly Assay Canister included in range. ISO 9001 / ISO 13485 manufactured in India.

Saxsons own-brand vertical laminar flow hoods for sterile radiopharmaceutical compounding. Lead-lined chassis (3 / 5 mm Pb) + HEPA H14 + UV + pre-filter + optional anti-microbial sweep. Class A / ISO 5 work zone. SS 202 standard inner; clean-room SS 304 inner + outer with integrated wash-basin. CE-marked motors. ISO 9001 / ISO 13485 manufactured in India.

Saxsons own-brand decontamination kit for radioactive-material spill response. Includes Bind-It™ chemical decontaminant, lead-lined decay drum (3/6 mm Pb tiers), full PPE pack (gloves, masks, coverall, shoe covers, caps), spill cordon (rope, sunboard signage, tags), surface cleaner, forceps. SPECT and PET variants. ISO 9001 / ISO 13485 manufactured in India.

Saxsons own-brand tiltable PET dose dispenser with integrated 3-part vial shield (30 mm Pb or 20 mm Tungsten). For FDG / Ga-68 / Cu-64 / Lu-177 multi-dose source-vial dispensing. Tiltable, swivel-jaw and with-rod mechanism variants. 15 cc Tungsten or 30 cc Lead vial geometries. Bench-mounted on the dispense L-bench. ISO 9001 / ISO 13485 manufactured in India.

Handheld intraoperative gamma detection platform — one console + 28+ probe models across CdTe and CsI(Tl) scintillator families. Covers Tc-99m (140 keV), I-125 (27 keV), In-111 (171/245 keV), I-131 (364 keV) and F-18 (511 keV with collimator). Probe library spans straight, curved, collimated, laparoscopic (frontal/lateral/45°) and wireless Bluetooth. Sentinel-node biopsy across breast, melanoma, gynaecological, ENT and urological cancers; ROLL (I-125); parathyroid surgery (Tc-99m-MIBI); recurrent thyroid (I-131). CE 0459 (G-Med Class IIa); FDA registered. Distributed in India by Saxsons Healthcare.
Iodine-125 seeds for non-palpable tumour localisation prior to surgical excision. Used in breast surgery and soft tissue. Wire-free technique.
Small field-of-view caesium iodide scintillation probe for intraoperative sentinel node detection. High spatial resolution with collimator. Autoclavable handle.

World-first single dual-channel probe — CdTe gamma + ICG NIR fluorescence detection in the same probe body. Two geometries: SOE 3214 (open, 12 mm Ø) and SOE 3214-AF (frontal laparoscopic, trans-trocar). Foot-switch modality control; operates under normal OR lighting; ICG sensitivity < 1 nmol. CdTe channel covers Tc-99m, I-125, In-111 (20–300 keV). Add-on module to the Europrobe 3.2 console — same hospital deployment upgrades to dual-modality without replacing the platform. EU MDR Class IIa (39483-0); FDA registered 9032627. Distributed in India by Saxsons Healthcare.
Perforated thermoplastic immobilisation mask for head and neck radiotherapy. Low-temperature activation at 65°C. Compatible with standard S-frame base plates.
Full-face thermoplastic immobilisation mask for cranial radiotherapy and SRS. High perforation for ventilation. Available in standard and paediatric sizes.
Full-body thermoplastic immobilisation shell for trunk and thorax radiotherapy. Multiple sizes. IGRT and IMRT workflow compatible.
Evacuatable positioning vacuum cushion for whole-body immobilisation. Silica bead fill. Available in 60×90cm and 70×100cm. Reproducible daily setup.

Patient-specific IMRT and VMAT quality assurance phantom with 3D dose verification. Complete QA report generated in under 20 minutes.

Flexible gold fiducial marker for soft-tissue IGRT tracking. 0.28mm diameter. MRI-compatible. Permanent soft-tissue anchoring. No migration.
Optically stimulated luminescence (OSL) personal radiation dosimeter for staff monitoring. IAEA-traceable calibration. Quarterly readout service.

3-axis Cartesian water phantom for linac commissioning and annual QA. ±0.1 mm accuracy. Automatic Detector Alignment System. SmartSelect automated scan queue. DICOM TPS export.

Daily linac QA device. All energies in one setup. Cable-free standalone operation. Automatic energy detection. Supports VMAT up to 2400 MU/min. Up to 9 rooms per session.

Reference-grade electrometer. Current range 0.001 pA to 500 nA. 0.1% repeatability. Leakage <1 fA. Digital filter. MAX COMM software for remote operation and data logging.

End-to-end stereotactic QA phantom. 0.1 mm component tolerance. SRS/SRT commissioning and ongoing QA. CT and MRI compatible. TG-142 analysis. Multi-frame system support.
Accurate and multifunctional SBRT positioning system. Adjustable belly and knee bridges. Compatible with Varian and Elekta couchtops. Integrates with vacuum cushions and thermoplastic masks.
MRI-compatible SBRT immobilization for MR-guided radiotherapy workflows. Integrates with vacuum cushions and thermoplastic masks in MR-linac environments.

Alderson Radiation Therapy anthropomorphic phantom — refined RANDO design, ICRU-44 tissue equivalence, 2.5 cm horizontal slices, bone-equivalent / lung-equivalent / soft-tissue-equivalent inserts. Male (175 cm / 73.5 kg / 36 sections) and female (155 cm / 50 kg / 33 sections) variants. Compatible with TLD / OSL / MOSFET / ion-chamber / film dosimetry. ~10,000 sites worldwide.

Saxsons own-brand fixed laser positioning system for accelerator / cobalt / simulator / CT-sim iso-centre indication. Each set: 2 cross lasers + 1 linear laser. Semiconductor red 635 nm Class II. Line width < 1 mm at 3–5 m. ISO-centre adjustment precision < 0.5 mm. Designed and manufactured in India by Saxsons Healthcare Pvt. Ltd.

Saxsons own-brand movable laser positioning system for precise patient positioning in radiotherapy. Red 635 nm Class II laser. Accuracy ±0.2 mm. One-axis / three-axis / five-axis movement configurations on exactitude linear guide rails with linear-coding closed-loop feedback. Control via computer / WiFi / manual control box. DICOM 3.0/RT compatible. Designed and manufactured in India by Saxsons Healthcare Pvt. Ltd.
Modular patient-positioning baseplate family for radiotherapy treatment setup — head / neck / shoulder, thorax, pelvis, breast and full-body indexed baseplates with interchangeable headrest cushion library, knee-foot supports, breast board, prone board, shoulder-retraction strap and arm supports. Carbon-fibre / radiolucent-composite construction with indexed locking holes at standard couch-bar pitch for repeatable inter-fraction setup. MRI-compatible variants for MR-linac and MR-sim workflows. AAPM TG-176 / ICRU 91 setup-reproducibility framework. CT, MR and DRR planning workflows.
Vacuum-bag immobilisation cushion family for SBRT, head-and-neck IMRT, lung, abdomen, pelvis and whole-body radiotherapy positioning. Polystyrene-bead fill in an airtight medical-grade polyurethane outer; one-touch quick-release valve compatible with standard hand and electric vacuum pumps. Conforms to the patient at simulation, locks into shape under vacuum, holds setup across the entire fraction series. Reusable across patients with standard wipe-down decontamination. Small / medium / large / extra-large body-region sizes. AAPM TG-101 SBRT and TG-178 IMRT immobilisation framework.

Comprehensive ten-component SBRT immobilisation system — couch-indexed platform with belly bridge, knee bridge, wing-board T-grip, knee + feet cushion, elevation cushion, T-shaped vacuum cushion, carbon-fibre headrest, lockable indexing bar and respiratory belt. The full AAPM TG-101 immobilisation chain for lung, liver, abdomen, pelvic and spine SBRT delivery. Clear scale marks on every adjustable component; quick-lock / unlock bridges; couch-vendor universal adapters.

Breast and lung positioning accessory family — Wing-Board T-Grip, supine + prone breast boards with cushions, and prone belly cushion. Supports supine tangential breast IMRT with DIBH heart-sparing, prone breast positioning (large breast or lung-sparing indication), lung tangential, and combined breast + nodal pelvic workflows. Radiolucent composite construction (<2 % beam attenuation), indexed to thorax baseplate. AAPM TG-66 breast-radiotherapy framework.