Saxsons Group
Saxsons own-brand lead-lined fume hood — stainless-steel work zone with counter-weighted clear sash, brushed-steel Saxsons brand header, radiation-caution decal and integrated stand with cabinet
3 / 5 / 6 / 10 / 12 mm
lead shielding options
SS 202 / SS 304
work-zone material
0.5 m/s
face velocity (AERB)
AMCA fan + CE motor
exhaust train
Active carbon (+HEPA)
filter pack
ISO 9001 / 13485
Saxsons-manufactured

Authorised Indian Distributor

Saxsons Group

New Delhi, India · Since 1997

SX
Nuclear Medicine NM-031 AERB Importable Saxsons own-brand · Made in India Configurable shielding 3–12 mm AERB 0.5 m/s face velocity

Saxsons Lead-Lined Fume Hood Hot-Lab Workstation — Configurable Across Shielding, Size, Filtration & Accessories

Saxsons own-brand lead-lined fume hood — a configurable hot-lab workstation manufactured in India in an ISO 9001 / ISO 13485 approved plant. Lead-shielded enclosure (3 / 5 / 6 / 10 / 12 mm options) with a stainless-steel-lined work zone, counter-weighted clear acrylic sash, CE-marked motor driving an AMCA-certified centrifugal fan through an active-carbon (and optional pre-filter + HEPA + UV) filtration train. Configured per site SOP — choose the size, shielding, materials, filter pack and accessory fit-out that match the workflow. Minimum face velocity 0.5 m/s per AERB guidelines.

Key Features

  • Saxsons own-brand product — designed and manufactured in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant
  • Lead-shielded enclosure with operator-selectable shielding thickness — 3 mm (routine NM), 5 / 6 mm (mid-activity), 10 / 12 mm (theranostic and high-activity workflows)
  • Stainless-steel-lined work zone (SS 202 standard; SS 304 on premium builds) — fully decontaminable wipe-down surfaces with coved corners
  • Counter-weighted clear acrylic sliding sash — effortless one-hand open / close; closes automatically on power-down
  • In-cabinet fluorescent or LED work-area lamp; external control panel with on/off switch, motor switch, tube-light switch, mains indicator and 3-pin socket
View all features

All Features

  • Saxsons own-brand product — designed and manufactured in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant
  • Lead-shielded enclosure with operator-selectable shielding thickness — 3 mm (routine NM), 5 / 6 mm (mid-activity), 10 / 12 mm (theranostic and high-activity workflows)
  • Stainless-steel-lined work zone (SS 202 standard; SS 304 on premium builds) — fully decontaminable wipe-down surfaces with coved corners
  • Counter-weighted clear acrylic sliding sash — effortless one-hand open / close; closes automatically on power-down
  • In-cabinet fluorescent or LED work-area lamp; external control panel with on/off switch, motor switch, tube-light switch, mains indicator and 3-pin socket
  • CE-marked exhaust motor driving an AMCA-certified centrifugal fan; standard active-carbon filter pack; HEPA + pre-filter + UV option available
  • Minimum face velocity 0.5 m/s at the sash opening, verified at the time of shipping per AERB guidelines
  • Accessory matrix configurable per workflow — hot-wire anemometer, negative-pressure sensor with 10″ PLC touch panel, movable body shield with lead-glass window, dose-calibrator ionisation-chamber mount, gamma-probe mount, 45 mm Capintec-type lead rings, lead-bricks front-wall shielding, generator + waste compartments
  • Standard 51 × 25 × 55 in footprint; small (41 × 23 × 51), mid (54 × 27 × 57 / 56 × 30 × 52 / 58 × 34 × 55), large (58 × 38 × 73) and compact (39 × 26 × 27) variants for probe / counter benches
  • Painted MS outer skin (standard) or full stainless outer (SS 202 / SS 304 premium builds) — choose per cleanroom-tier expectations
  • Stand with optional unshielded bottom cabinet for routine-supplies storage; stand-free variants for benchtop deployment
  • Indian power connection standard; export voltage variants on request
  • Documentation: site-specific build sheet, IQ / OQ / PQ protocols, factory face-velocity certificate, AERB compliance paperwork, Saxsons-branded operator manual

Technical Specifications

Brand / build Saxsons own-brand — manufactured in India by Saxsons Healthcare Pvt. Ltd., ISO 9001 / ISO 13485 approved plant
Lead shielding options 3 mm · 5 mm · 6 mm · 10 mm · 12 mm (operator-selected per workflow)
External dimensions Standard 51 × 25 × 55 in (L × W × H without stand); small / mid / large / compact variants — see variant matrix below
Inner work-zone (Std) 42 × 18 × 29 in (Standard 51-in frame); 32.16 × 18.32 × 29.5 in (Small 41-in frame); 48 × 32 × 48 in (Large 58-in frame)
Inner material Stainless steel — SS 202 (standard) or SS 304 (premium / heavier shielding builds)
Outer material MS painted finish (standard); SS 202 or SS 304 (premium full-stainless builds)
Sash Counter-weighted clear acrylic sliding sash; effortless open / close
Lighting Fluorescent or LED work-zone lamp; control switch on external panel
Exhaust motor CE-marked universal AC motor; on/off switch on external panel
Exhaust fan AMCA-certified standard centrifugal fan; heavy-duty centrifugal blower on premium builds
Filter pack — standard Active-carbon (charcoal) filter on the exhaust path
Filter pack — premium Pre-filter + HEPA + active-carbon (optional UV light) — for higher-particulate / cleaner-room fit-outs
Face velocity ≥ 0.5 m/s at the sash opening, verified at the time of shipping per AERB guidelines
Differential-pressure monitoring (option) Negative-pressure sensor with 10″ PLC touch panel for live across-filter ΔP feedback; flags choke-state before face velocity drifts
Power connection Indian power connection standard; export voltage variants on request
Stand Frame stand standard; unshielded bottom-cabinet variant for routine supplies; stand-free benchtop variant for compact 39-in frame
Compliance framework AERB Safety Code for Nuclear Medicine Facility, ISO 9001, ISO 13485, AMCA fan certification, CE-marked motors
Documentation Site build sheet, IQ / OQ / PQ protocols, factory face-velocity certificate, AERB compliance paperwork, Saxsons-branded operator manual

Applications

One cabinet family across Tc-99m, F-18, Ga-68, Lu-177 and I-131 dispensing workflows

Tc-99m generator elution + kit dispensing

Daily Tc-99m kit reconstitution and dispensing inside a 3–6 mm lead-shielded enclosure. Generator compartment variant houses the Tc-99m generator inside the cabinet; the dispensing line runs alongside without separate room shielding.

F-18 PET dose dispensing

Per-patient [18F]FDG / [18F]NaF unit-dose dispensing from a transport vial. 5–6 mm shielding plus the optional 45 mm Capintec-type lead rings cover the 511 keV annihilation line at typical PET unit-dose activities.

Lu-177 + Ga-68 theranostic dispensing

10–12 mm shielding option for theranostic dispensing programmes — Lu-177 DOTATATE / PSMA-617 and Ga-68 generator elution. PLC + body-shield premium build adds operator-side dose-rate management for routine high-activity dispensing.

I-131 capsule + solution handling

I-131 capsule dispense and oral-solution decant — active-carbon filter + optional HEPA captures volatile radioiodine on the exhaust before site-stack release.

In-cabinet dose-calibrator workflow

Dose-calibrator ionisation-chamber-mount variant integrates an end-user-supplied dose calibrator inside the cabinet, with the display mounted externally. Removes a separate dispensing-bench footprint from the hot-lab fit-out.

AERB inspection-ready hot-lab fit-out

Lockable cabinet, factory face-velocity certificate, daily anemometer log (when anemometer is fitted) and the AERB compliance paperwork pack — the cabinet ships ready for first-inspection sign-off and slots into the routine inspection dossier thereafter.

Why Saxsons Lead-Lined Fume Hood?

0.5 m/s
AERB face velocity

AERB Safety Code for Nuclear Medicine Facility expects a minimum 0.5 m/s face velocity at the sash opening on dispensing fume hoods. Every Saxsons-built cabinet ships with a factory-issued face-velocity certificate at the time of shipping, and the optional hot-wire anemometer keeps the operator within spec day to day.

3–12 mm
Shielding selectable

Routine Tc-99m kit dispensing runs at 3 mm. Mid-activity F-18 / Ga-68 / Lu-177 dispensing runs at 5 / 6 mm. Theranostic high-activity prep runs at 10 / 12 mm. One cabinet family covers the whole NM activity range — choose the shielding tier for the workflow, not for the whole department.

Made in India
Saxsons own-brand

Designed and built in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant. Local manufacture cuts lead times, local engineering means site-specific build sheets, and the AERB compliance paperwork lands first time because the build is documented to the AERB framework.

Variant matrix

Configure the cabinet for the workflow

Five axes — size, shielding, material, filter pack and accessory fit-out. The site- specific build sheet locks the combination that matches the dispensing programme and the AERB licence; the same chassis family covers everything from a satellite-imaging probe bench to a theranostic high-activity prep room.

Size variants — external L × W × H (in)

Frame External (in) Notes
Compact 39 × 26 × 27 in Probe / counter bench, side-station
Small 41 × 23 × 51 in Inner 32.16 × 18.32 × 29.5 in; entry / satellite hot lab
Standard 51 × 25 × 55 in Inner 42 × 18 × 29 in; the workhorse footprint
Standard+ 52 × 25.7 × 55 in Slight overhang option; pairs with optional anemometer
Mid 54 × 27 × 57 in Heavier shielding fit, deeper work zone
Mid+ 56 × 30 × 52 in HEPA + lead-rings + generator-compartment fit-out
Mid Premium 58 × 34 × 55 in PLC + body-shield premium build
Large 58 × 38 × 73 in Inner 48 × 32 × 48 in; high-throughput hot lab
Wide-low 66 × 35 × 49 in Lead-bricks front shielding + dose-calibrator bench

Filter packs

Standard Active-carbon filter on exhaust; covers Tc-99m / F-18 routine dispensing
HEPA + Charcoal Pre-filter + HEPA + active-carbon (+ optional UV light); for higher-particulate or cleaner-room fit-outs
Generator + Waste compartment Integrated Tc-99m generator compartment + shielded waste compartment with HEPA filtration and lead-glass viewing

Accessories Matrix

Hot-wire anemometer Live face-velocity readout for AERB 0.5 m/s sash check
Negative-pressure sensor + 10″ PLC touch panel Across-filter pressure differential with PLC feedback; flags choke-state before face velocity drifts
Movable body shield with lead-glass window External adjustable splash / line-of-sight shield for dispensing; integrates with the cabinet sash
Dose-calibrator ionisation-chamber mount Internal mounting for an end-user-supplied dose calibrator with external display; eliminates a separate bench
Gamma-probe mount Internal probe geometry for in-cabinet Tc-99m / F-18 wipe assay
Lead-rings (45 mm Capintec-type) Dose-calibrator vial / syringe geometry shielding; matches standard counter geometries
Lead-bricks front-wall shielding Supplementary shielding ahead of the dispensing line for high-activity work
UV light + LED work-zone lamp Surface decontamination cycle + bright work-zone lighting

Site-specific build sheet locks the size × shielding × material × filter × accessory combination per workflow. Each Saxsons-built unit ships with a factory face-velocity certificate, IQ / OQ / PQ protocols and the AERB compliance paperwork pack.

Available through Saxsons Group

The Saxsons-built hot-lab workstation, configured for your workflow

Contact Saxsons Healthcare Pvt. Ltd. for site-specific build sheet, shielding-tier selection, accessory matrix, IQ / OQ / PQ documentation and AERB compliance paperwork — designed and manufactured in India.