Saxsons Group — India's trusted nuclear medicine, radiotherapy, oncosurgery, dosimetry and cyclotron supplier since 1986
Saxsons own-brand lead-lined fume hood — stainless-steel work zone with counter-weighted clear sash, brushed-steel Saxsons brand header, radiation-caution decal and integrated stand with cabinet
Configurable
lead-shielding tiers
Stainless steel
work-zone material
AERB-compliant
face velocity
AMCA fan + CE motor
exhaust train
Sterile-compounding-grade
filter pack
ISO 9001 / 13485
Saxsons-manufactured

Authorised Indian Distributor

Saxsons Group

New Delhi, India · Since 1997

SX
Nuclear MedicineNM-031Saxsons own-brand · Made in IndiaConfigurable shielding tiersAERB face-velocity certified

Saxsons Lead-Lined Fume HoodHot-Lab Workstation — Configurable Across Shielding, Size, Filtration & Accessories

Saxsons own-brand lead-lined fume hood — a configurable hot-lab workstation manufactured in India in an ISO 9001 / ISO 13485 approved plant. Lead-shielded enclosure across a full tier ladder with a stainless-steel-lined work zone, counter-weighted clear acrylic sash, CE-marked motor driving an AMCA-certified centrifugal fan through a sterile-compounding-grade filter pack. Configured per site SOP — choose the size, shielding, materials, filter pack and accessory fit-out that match the workflow. AERB-compliant face-velocity certification at shipping. Sign in to view the complete configuration matrix.

Key Features

  • Saxsons own-brand product — designed and manufactured in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant
  • Lead-shielded enclosure with an operator-selectable shielding tier spanning routine NM, mid-activity and theranostic / high-activity workflows
  • Stainless-steel-lined work zone — fully decontaminable wipe-down surfaces with coved corners; medical-grade upgrade available
  • Counter-weighted clear acrylic sliding sash — effortless one-hand open / close; closes automatically on power-down
  • In-cabinet fluorescent or LED work-area lamp; external control panel with on/off switch, motor switch, tube-light switch, mains indicator and 3-pin socket
View all features
Enquire / Get Price← Nuclear Medicine Range

All Features

  • Saxsons own-brand product — designed and manufactured in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant
  • Lead-shielded enclosure with an operator-selectable shielding tier spanning routine NM, mid-activity and theranostic / high-activity workflows
  • Stainless-steel-lined work zone — fully decontaminable wipe-down surfaces with coved corners; medical-grade upgrade available
  • Counter-weighted clear acrylic sliding sash — effortless one-hand open / close; closes automatically on power-down
  • In-cabinet fluorescent or LED work-area lamp; external control panel with on/off switch, motor switch, tube-light switch, mains indicator and 3-pin socket
  • CE-marked exhaust motor driving an AMCA-certified centrifugal fan; sterile-compounding-grade filter pack (premium filter train option available)
  • AERB-compliant face velocity at the sash opening, verified at the time of shipping
  • Accessory matrix configurable per workflow — hot-wire anemometer, negative-pressure sensor with PLC touch panel, movable body shield with lead-glass window, dose-calibrator ionisation-chamber mount, gamma-probe mount, Capintec-type lead rings, lead-bricks front-wall shielding, generator + waste compartments
  • Full frame-size ladder — compact, small, standard, mid and large chassis for probe / counter benches through high-throughput hot labs
  • Painted MS outer skin (standard) or full stainless outer (premium builds) — choose per cleanroom-tier expectations
  • Stand with optional unshielded bottom cabinet for routine-supplies storage; stand-free variants for benchtop deployment
  • Indian power connection standard; export voltage variants on request
  • Documentation: site-specific build sheet, IQ / OQ / PQ protocols, factory face-velocity certificate, AERB compliance paperwork, Saxsons-branded operator manual

Technical Specifications

Brand / buildSaxsons own-brand — manufactured in India by Saxsons Healthcare Pvt. Ltd., ISO 9001 / ISO 13485 approved plant
Configuration optionsMultiple shielding tiers, frame sizes, work-zone / outer materials and filter/accessory packs — full ladder in the sign-in variant matrix
Inner materialStainless-steel-lined work zone; medical-grade upgrade available
Outer materialMS painted finish (standard); full-stainless premium builds
SashCounter-weighted clear acrylic sliding sash; effortless open / close
LightingFluorescent or LED work-zone lamp; control switch on external panel
Exhaust motorCE-marked universal AC motor; on/off switch on external panel
Exhaust fanAMCA-certified standard centrifugal fan; heavy-duty centrifugal blower on premium builds
Filter packSterile-compounding-grade filter pack; premium filter train option available
Face velocityAERB-compliant face velocity at the sash opening, verified at the time of shipping
Differential-pressure monitoring (option)Negative-pressure sensor with PLC touch panel for live across-filter ΔP feedback; flags choke-state before face velocity drifts
Power connectionIndian power connection standard; export voltage variants on request
StandFrame stand standard; unshielded bottom-cabinet variant for routine supplies; stand-free benchtop variant for the compact frame
Compliance frameworkAERB Safety Code for Nuclear Medicine Facility, ISO 9001, ISO 13485, AMCA fan certification, CE-marked motors
DocumentationSite build sheet, IQ / OQ / PQ protocols, factory face-velocity certificate, AERB compliance paperwork, Saxsons-branded operator manual

Applications

One cabinet family across Tc-99m, F-18, Ga-68, Lu-177 and I-131 dispensing workflows

Tc-99m generator elution + kit dispensing

Daily Tc-99m kit reconstitution and dispensing inside a lead-shielded enclosure at the routine SPECT tier. Generator compartment variant houses the Tc-99m generator inside the cabinet; the dispensing line runs alongside without separate room shielding.

F-18 PET dose dispensing

Per-patient [18F]FDG / [18F]NaF unit-dose dispensing from a transport vial. Mid-tier shielding plus the optional Capintec-type lead rings cover the 511 keV annihilation line at typical PET unit-dose activities.

Lu-177 + Ga-68 theranostic dispensing

Heavier-tier shielding option for theranostic dispensing programmes — Lu-177 DOTATATE / PSMA-617 and Ga-68 generator elution. PLC + body-shield premium build adds operator-side dose-rate management for routine high-activity dispensing.

I-131 capsule + solution handling

I-131 capsule dispense and oral-solution decant — sterile-compounding-grade filter pack captures volatile radioiodine on the exhaust before site-stack release.

In-cabinet dose-calibrator workflow

Dose-calibrator ionisation-chamber-mount variant integrates an end-user-supplied dose calibrator inside the cabinet, with the display mounted externally. Removes a separate dispensing-bench footprint from the hot-lab fit-out.

AERB inspection-ready hot-lab fit-out

Lockable cabinet, factory face-velocity certificate, daily anemometer log (when anemometer is fitted) and the AERB compliance paperwork pack — the cabinet ships ready for first-inspection sign-off and slots into the routine inspection dossier thereafter.

Why Saxsons Lead-Lined Fume Hood?

Certified
AERB face velocity

AERB Safety Code for Nuclear Medicine Facility expects a minimum face velocity at the sash opening on dispensing fume hoods. Every Saxsons-built cabinet ships with a factory-issued face-velocity certificate at the time of shipping, and the optional hot-wire anemometer keeps the operator within spec day to day.

Configurable
Shielding selectable

Routine Tc-99m kit dispensing, mid-activity F-18 / Ga-68 / Lu-177 dispensing and theranostic high-activity prep each pick a different shielding tier. One cabinet family covers the whole NM activity range — choose the shielding tier for the workflow, not for the whole department.

Made in India
Saxsons own-brand

Designed and built in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant. Local manufacture cuts lead times, local engineering means site-specific build sheets, and the AERB compliance paperwork lands first time because the build is documented to the AERB framework.

✨ Configuration matrix · for signed-in customers

Detailed configurations are also available for your view

Frame sizes, lead-shielding tiers, work-zone materials, filter packs and the accessory matrix for the hot-lab fume hood family. Sign in or create a free Saxsons account to view.

Other benefits of a Saxsons account

  • Full configuration matrices across the whole Saxsons own-brand catalogue — shielding tiers, closures, accessories, per-workflow build sheets

  • Personal Literature Radar library — ★ save, ⌛ read-later and 📎 refer-later on peer-reviewed papers across theranostics, radiotherapy QA, dosimetry, hot-lab QC

  • Weekly literature digest — plain-text email summary of new peer-reviewed papers for the topics you follow

  • Faster quote turnaround — approved accounts skip the per-quote verification step and land straight with the Saxsons sales team

  • Per-site configuration proposals — request bespoke shielding drawings, vial-geometry inserts and site-IQ documentation

  • Early access to new Saxsons own-brand product launches, brochures and knowledge-hub content

Sign-up takes about 30 seconds — institutional email + hospital name. Accounts are reviewed by the Saxsons sales team. No promotional emails.

Saxsons own-brand · Variant brochure

Request the full Saxsons Lead-Lined Fume Hood variant brochure

The detailed variant matrix, dimensions, accessories and AERB import documentation are not published on this page. Tell us who you are and a Saxsons sales engineer will email the brochure to your institutional address within one working day.

Brochure dispatch is reviewed by a sales engineer before sending — we may verify by phone.

FAQ

Lead-lined fume hood, hot-lab containment, AERB face velocity — questions we hear from Indian radiopharmacy teams

Why chemistry-grade fume hoods are not enough for radioactive work, how to pick the right lead thickness for your isotope mix, how the AMCA + AERB face-velocity certification fits the AERB dossier, and what the variant matrix covers.

Q.Why does a nuclear-medicine hot lab need a specialised fume hood rather than a standard chemistry fume hood?

A standard chemistry fume hood pulls chemical vapour up and out — it does nothing about ionising radiation. A radiopharmacy hot lab handles Tc-99m, F-18, Ga-68, I-131 and Lu-177 sources at diagnostic and therapy doses, so the workstation has to combine two independent controls in one enclosure: containment (HEPA + activated carbon capture of radioactive aerosol) and shielding (lead thickness rated for the highest-energy photon on the bench). A lead-lined fume hood is the engineered control that fulfils both.

Q.How is the right lead thickness for a given hot-lab picked?

Lead thickness is picked against the isotope mix the department dispenses. 3 mm Pb covers routine Tc-99m SPECT (140 keV). 5–6 mm covers Ga-67 / In-111 mid-energy work. 10–12 mm is the tier for 511 keV PET (F-18 / Ga-68) and I-131 therapy. The Saxsons fume-hood family carries five shielding tiers (3 / 5 / 6 / 10 / 12 mm Pb) so the department picks the tier that matches its actual isotope workload rather than paying for shielding it does not need.

Q.What problem does the AMCA-certified fan + AERB face-velocity certification solve?

AERB Safety Code for Nuclear Medicine Facility requires the fume-hood face velocity to sit at 0.5 m/s ± tolerance for the containment claim to hold — outside that window, aerosol capture drops off. AMCA-certified fans deliver flow within the specification window across the operating life of the hood, and every Saxsons hood ships with a face-velocity certification traceable to the shipping test — the department has the AERB inspection-ready document from day one.

Q.What variant configurations does the fume-hood family support?

The variant matrix covers 9 frame sizes (compact through large premium), 5 lead-shielding tiers (3 / 5 / 6 / 10 / 12 mm), 2 work-zone material grades (SS-202 standard / SS-304 medical), 2 filter packs (activated carbon or HEPA + UV), and accessory options — anemometer, negative-pressure PLC, body shield, dose-calibrator ionisation-chamber mount, gamma-probe mount, Capintec-type lead rings, generator and waste compartments. The full matrix locks into a per-site IQ / OQ / PQ build sheet at order.

Q.Is this a distributor-supplied hood or Saxsons-manufactured?

The Lead-Lined Fume Hood family is a Saxsons own-brand product — designed and manufactured in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant. Not a rebadged import; the shielding tiers, work-zone materials, filter packs and accessory options are engineered specifically for the workload and hot-lab footprint constraints of Indian NM departments.

Saxsons Lead-Lined Fume Hood supplier in India — Saxsons Group

Saxsons Group has supplied nuclear medicine equipment to over 1,000 Indian hospitals since 1988. Every consignment of Saxsons Lead-Lined Fume Hood ships with cold-chain logistics, AERB import documentation, CDSCO registration references and a Certificate of Analysis delivered before dispatch — the paperwork your radiation-safety and procurement teams need, pre-assembled.

  • Nationwide delivery footprint — every metro and tier-2 city in India, scheduled to your treatment / procedure calendar.
  • AERB & CDSCO documentation — import licence, radiation-safety paperwork and RSO briefing pre-assembled for the audit file.
  • 40+ years in Indian oncology — long-standing supply relationships with AIIMS, Tata Memorial, and hundreds of tertiary-care centres.
  • Single point of accountability — one purchase order, one delivery contact, one after-sales team across the whole product family.
Available through Saxsons Group

The Saxsons-built hot-lab workstation, configured for your workflow

Contact Saxsons Healthcare Pvt. Ltd. for site-specific build sheet, shielding-tier selection, accessory matrix, IQ / OQ / PQ documentation and AERB compliance paperwork — designed and manufactured in India.