Thermoplastic Head Mask — S-Frame
Perforated thermoplastic immobilisation mask for head and neck radiotherapy. Low-temperature activation at 65°C. Compatible with standard S-frame base plates.
Radiotherapy immobilisation and positioning accessories for Indian hospitals.
Perforated thermoplastic immobilisation mask for head and neck radiotherapy. Low-temperature activation at 65°C. Compatible with standard S-frame base plates.
Full-face thermoplastic immobilisation mask for cranial radiotherapy and SRS. High perforation for ventilation. Available in standard and paediatric sizes.
Full-body thermoplastic immobilisation shell for trunk and thorax radiotherapy. Multiple sizes. IGRT and IMRT workflow compatible.
Evacuatable positioning vacuum cushion for whole-body immobilisation. Silica bead fill. Available in 60×90cm and 70×100cm. Reproducible daily setup.
Patient-specific IMRT and VMAT quality assurance phantom with 3D dose verification. Complete QA report generated in under 20 minutes.
Flexible gold fiducial marker for soft-tissue IGRT tracking. 0.28mm diameter. MRI-compatible. Permanent soft-tissue anchoring. No migration.
Optically stimulated luminescence (OSL) personal radiation dosimeter for staff monitoring. IAEA-traceable calibration. Quarterly readout service.
3-axis Cartesian water phantom for linac commissioning and annual QA. ±0.1 mm accuracy. Automatic Detector Alignment System. SmartSelect automated scan queue. DICOM TPS export.
Daily linac QA device. All energies in one setup. Cable-free standalone operation. Automatic energy detection. Supports VMAT up to 2400 MU/min. Up to 9 rooms per session.
Reference-grade electrometer. Current range 0.001 pA to 500 nA. 0.1% repeatability. Leakage <1 fA. Digital filter. MAX COMM software for remote operation and data logging.
End-to-end stereotactic QA phantom. 0.1 mm component tolerance. SRS/SRT commissioning and ongoing QA. CT and MRI compatible. TG-142 analysis. Multi-frame system support.
Accurate and multifunctional SBRT positioning system. Adjustable belly and knee bridges. Compatible with Varian and Elekta couchtops. Integrates with vacuum cushions and thermoplastic masks.
MRI-compatible SBRT immobilization for MR-guided radiotherapy workflows. Integrates with vacuum cushions and thermoplastic masks in MR-linac environments.
Alderson Radiation Therapy anthropomorphic phantom — refined RANDO design, ICRU-44 tissue equivalence, 2.5 cm horizontal slices, bone-equivalent / lung-equivalent / soft-tissue-equivalent inserts. Male (175 cm / 73.5 kg / 36 sections) and female (155 cm / 50 kg / 33 sections) variants. Compatible with TLD / OSL / MOSFET / ion-chamber / film dosimetry. ~10,000 sites worldwide.
Saxsons own-brand fixed laser positioning system for accelerator / cobalt / simulator / CT-sim iso-centre indication. Each set: 2 cross lasers + 1 linear laser. Semiconductor red 635 nm Class II. Line width < 1 mm at 3–5 m. ISO-centre adjustment precision < 0.5 mm. Designed and manufactured in India by Saxsons Healthcare Pvt. Ltd.
Saxsons own-brand movable laser positioning system for precise patient positioning in radiotherapy. Red 635 nm Class II laser. Accuracy ±0.2 mm. One-axis / three-axis / five-axis movement configurations on exactitude linear guide rails with linear-coding closed-loop feedback. Control via computer / WiFi / manual control box. DICOM 3.0/RT compatible. Designed and manufactured in India by Saxsons Healthcare Pvt. Ltd.
Modular patient-positioning baseplate family for radiotherapy treatment setup — head / neck / shoulder, thorax, pelvis, breast and full-body indexed baseplates with interchangeable headrest cushion library, knee-foot supports, breast board, prone board, shoulder-retraction strap and arm supports. Carbon-fibre / radiolucent-composite construction with indexed locking holes at standard couch-bar pitch for repeatable inter-fraction setup. MRI-compatible variants for MR-linac and MR-sim workflows. AAPM TG-176 / ICRU 91 setup-reproducibility framework. CT, MR and DRR planning workflows.
Vacuum-bag immobilisation cushion family for SBRT, head-and-neck IMRT, lung, abdomen, pelvis and whole-body radiotherapy positioning. Polystyrene-bead fill in an airtight medical-grade polyurethane outer; one-touch quick-release valve compatible with standard hand and electric vacuum pumps. Conforms to the patient at simulation, locks into shape under vacuum, holds setup across the entire fraction series. Reusable across patients with standard wipe-down decontamination. Small / medium / large / extra-large body-region sizes. AAPM TG-101 SBRT and TG-178 IMRT immobilisation framework.
Comprehensive ten-component SBRT immobilisation system — couch-indexed platform with belly bridge, knee bridge, wing-board T-grip, knee + feet cushion, elevation cushion, T-shaped vacuum cushion, carbon-fibre headrest, lockable indexing bar and respiratory belt. The full AAPM TG-101 immobilisation chain for lung, liver, abdomen, pelvic and spine SBRT delivery. Clear scale marks on every adjustable component; quick-lock / unlock bridges; couch-vendor universal adapters.
Breast and lung positioning accessory family — Wing-Board T-Grip, supine + prone breast boards with cushions, and prone belly cushion. Supports supine tangential breast IMRT with DIBH heart-sparing, prone breast positioning (large breast or lung-sparing indication), lung tangential, and combined breast + nodal pelvic workflows. Radiolucent composite construction (<2 % beam attenuation), indexed to thorax baseplate. AAPM TG-66 breast-radiotherapy framework.