Saxsons Group — India's trusted nuclear medicine, radiotherapy, oncosurgery, dosimetry and cyclotron supplier since 1986
Saxsons tiltable PET dose dispenser — stainless-steel bench-mount chassis with 3-part lead pot, swivel-jaw mechanism and integrated needle-access top cap
Lead or Tungsten
shielding tier options
3-part vial shield
Top cap + Middle cap + Base
Standard PET vials
compatible vial geometries
Tiltable + Swivel-jaw
two ergonomic variants
Bench-mount
compact footprint
ISO 9001 / 13485
Saxsons-manufactured

Authorised Indian Distributor

Saxsons Group

New Delhi, India · Since 1997

SX
Nuclear MedicineNM-046Saxsons own-brand · Made in IndiaLead or Tungsten shield3-part vial shieldTiltable + Swivel-jaw variants

Saxsons™ Dose DispenserTiltable PET Dose-Withdrawal System with 3-Part Lead or Tungsten Vial Shield

Saxsons own-brand tiltable dose dispenser — the bench-mounted PET dose-withdrawal system that brings the vial neck to the operator syringe without lifting the vial out of the shielded chamber. Two shielding-tier families: a 3-part Lead Pot (RPDD1-A series) or a 3-part Tungsten vial shield (RPDD-J-HRT series) — picked per the radiopharmacy lead vs tungsten preference. Tiltable mechanism + 3-part architecture (top cap + middle cap + base) means only the top cap moves per dispense; the vial stays in the shielded position across the full multi-dispense campaign. Swivel-jaw and with-rod ergonomic variants. Bench-mounted compact footprint pairs with the Saxsons L-Bench PET (NM-036), Lead-Lined Fume Hood (NM-031) and PET tungsten syringe shield range. Designed and manufactured in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant. Sign in to view the complete configuration matrix.

Key Features

  • Saxsons own-brand product — designed and manufactured in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant
  • Tiltable lead-pot mechanism — operator tilts the shielded vial pot to bring the needle hole down to the syringe without lifting the vial out of the shielded chamber
  • 3-part Lead Pot architecture — Top Cap (closes the needle hole) + Middle Cap (with needle access hole) + Base (holds the vial); only the top cap moves per dispense
  • Lead-shielded tier — pairs with the Saxsons Lead Vial Shield (NM-034, 3-part PET) for routine FDG / Ga-68 / Cu-64 dispensing
  • Tungsten-shielded tier — pairs with the Saxsons Tungsten Vial Shield (NM-035, 3-part PET) for radiopharmacies that prefer tungsten's high-Z high-density chassis
View all features
Enquire / Get Price← Nuclear Medicine Range

All Features

  • Saxsons own-brand product — designed and manufactured in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant
  • Tiltable lead-pot mechanism — operator tilts the shielded vial pot to bring the needle hole down to the syringe without lifting the vial out of the shielded chamber
  • 3-part Lead Pot architecture — Top Cap (closes the needle hole) + Middle Cap (with needle access hole) + Base (holds the vial); only the top cap moves per dispense
  • Lead-shielded tier — pairs with the Saxsons Lead Vial Shield (NM-034, 3-part PET) for routine FDG / Ga-68 / Cu-64 dispensing
  • Tungsten-shielded tier — pairs with the Saxsons Tungsten Vial Shield (NM-035, 3-part PET) for radiopharmacies that prefer tungsten's high-Z high-density chassis
  • Swivel-jaw mechanism variant (RPDD1-C series) — alternate ergonomic style; swivel rotation brings the vial neck to the operator-syringe at a fixed working height
  • With-rod variant (RPDDS-B / RPDD1-B series) — rod-actuated tilt for operators who prefer mechanical tilt-leverage over jaw rotation
  • Bench-mounted compact footprint — sits on the dispense L-bench worktop next to the dose calibrator and syringe-shield station
  • Compatible with the standard PET vial geometries across the Lead and Tungsten 3-part shield ranges
  • Pairs with the Saxsons Dose Cabinet (NM-013), L-Bench PET (NM-036), Lead-Lined Fume Hood (NM-031) and Lead / Tungsten Vial Shield range for end-to-end Saxsons-built dispense workflow
  • Documentation: per-batch material certificate, ISO 9001 / ISO 13485 quality records

Technical Specifications

Brand / buildSaxsons own-brand — manufactured in India by Saxsons Healthcare Pvt. Ltd., ISO 9001 / ISO 13485 approved plant
Configuration optionsMultiple shielding tiers (Lead / Tungsten 3-part) across tilt / swivel-jaw / with-rod mechanism variants — full ladder in the sign-in variant matrix
Mechanism variantsTiltable (RPDD1-A) · Swivel-jaw (RPDD1-C) · With-rod (RPDDS-B / RPDD1-B)
Vial-shield architecture3-part — Top Cap (closes needle hole) + Middle Cap (needle access hole) + Base (holds vial)
Compatible vial geometriesStandard PET vial geometries across the Lead and Tungsten 3-part shield ranges — full range in the sign-in variant matrix
Bench-mount footprintCompact bench-mount chassis; sits on the dispense L-bench worktop
Pairs withSaxsons Lead Vial Shield (NM-034) · Tungsten Vial Shield (NM-035) · L-Bench PET (NM-036) · Dose Cabinet (NM-013) · Lead-Lined Fume Hood (NM-031)
Target isotopesF-18 (FDG / PSMA / PSMA-1007) · Ga-68 (DOTATATE / DOTATOC / PSMA-11) · Cu-64 · Lu-177 (theranostic) — anything dispensed from a multi-dose source vial
Compliance frameworkAERB Safety Code for Nuclear Medicine Facility · ICRP Publication 103 · ISO 9001 / ISO 13485
DocumentationPer-batch material certificate · ISO quality-record pack

Applications

Source-vial stays in the shielded base · only the top cap moves per dispense

[¹⁸F]FDG multi-dose source-vial dispensing

Lead-shielded tier · 3-part Lead Pot. Source vial sits in the base; per-dispense the operator tilts to bring the needle hole to the syringe, withdraws the dose, releases the tilt and the vial returns to upright shielded position.

Ga-68 PET tracer dispensing

Lead-shielded tier covers Ga-68-DOTATATE / DOTATOC / PSMA-11 per-elution dispensing. Same 3-part architecture, same tilt-and-withdraw workflow.

High-activity Lu-177 theranostic dispensing

Tungsten-shielded tier — pairs with the Tungsten 3-part vial shield. The smaller, denser chassis fits Lu-177 PRRT prep with the compact PET vial geometry.

Multi-dispense campaign workflow

Source vial stays in the base across all 25–40 per-shift dispenses; only the top cap moves per dispense. The vial is not lifted out, not re-shielded, not re-handled — minimises operator exposure cumulatively across the shift.

Pairs with Saxsons L-Bench PET workflow

The bench-mount dispenser sits on the Saxsons L-Bench PET worktop (NM-036) next to the dose calibrator. The full Saxsons dispense workflow — fume hood + L-bench + dose dispenser + vial shield + syringe shield + sharps container + waste bin — covers the end-to-end PET dispense cycle.

Ergonomic style choice — tilt / swivel / rod

Three mechanism variants for the same shielding tier. Tilt is the workhorse; swivel-jaw is ergonomic for fixed-height operators; with-rod is the leverage-preferred variant. The radiopharmacy picks per operator preference; the shielded outcome is identical.

Why Saxsons™ Dose Dispenser?

3-part
Vial stays in the shielded base

Top cap closes the needle hole; middle cap has the needle-access hole; base holds the vial. Per-dispense: lift top cap, withdraw dose, replace top cap. The vial NEVER comes out of the shielded base across the multi-dispense campaign. Operator hand never approaches an unshielded vial.

Tilt
Brings the vial to the syringe

The dose-withdrawal step is where operator extremity dose accumulates. A tiltable dispenser brings the needle hole DOWN to the operator-held syringe — the operator hand stays at the syringe plunger, the vial stays in the shielded base. Per-dispense extremity dose drops measurably vs lift-out-and-withdraw.

Pb or W
Two shielding tiers

Lead-shielded tier is the radiopharmacy workhorse (3-part Lead Pot). Tungsten-shielded tier offers an alternate chassis for radiopharmacies that prefer tungsten's high-Z high-density compactness. Same dispense workflow, same 3-part architecture.

✨ Configuration matrix · for signed-in customers

Detailed configurations are also available for your view

Vial-shield material and shielding-tier options, tilt/swivel mechanism variants and per-tracer dispensing configurations. Sign in or create a free Saxsons account to view.

Other benefits of a Saxsons account

  • Full configuration matrices across the whole Saxsons own-brand catalogue — shielding tiers, closures, accessories, per-workflow build sheets

  • Personal Literature Radar library — ★ save, ⌛ read-later and 📎 refer-later on peer-reviewed papers across theranostics, radiotherapy QA, dosimetry, hot-lab QC

  • Weekly literature digest — plain-text email summary of new peer-reviewed papers for the topics you follow

  • Faster quote turnaround — approved accounts skip the per-quote verification step and land straight with the Saxsons sales team

  • Per-site configuration proposals — request bespoke shielding drawings, vial-geometry inserts and site-IQ documentation

  • Early access to new Saxsons own-brand product launches, brochures and knowledge-hub content

Sign-up takes about 30 seconds — institutional email + hospital name. Accounts are reviewed by the Saxsons sales team. No promotional emails.

Saxsons own-brand · Variant brochure

Request the full Saxsons™ Dose Dispenser variant brochure

The detailed variant matrix, dimensions, accessories and AERB import documentation are not published on this page. Tell us who you are and a Saxsons sales engineer will email the brochure to your institutional address within one working day.

Brochure dispatch is reviewed by a sales engineer before sending — we may verify by phone.

Saxsons™ Dose Dispenser

More for this product

Each card opens a focused post for a specific specialty — peer-reviewed evidence and clinical workflow, written for the persona you select.

FAQ

Tiltable PET dose dispenser — questions we hear from Indian PET / theranostic teams

Why manual PET dispensing burns extremity dose, when to pick Pb vs W vial shield with the dispenser, which PET workflows it fits, and what the four-piece dispensing-line pairing looks like.

Q.What manual step in PET dose dispensing does the tiltable dose dispenser eliminate?

Manual PET dispensing requires the technologist to hold the vial with one hand, hold the syringe with the other, and eyeball the septum penetration under a lead-glass window — all while the 511 keV vial sits within centimetres of the operator hand. The tiltable dose dispenser holds the vial in a fixed 3-part shielded body and tilts it to the correct dispensing angle mechanically; the technologist puts both hands on the syringe alone, at a safer distance from the vial body. Extremity dose per dispensing drops.

Q.Lead or tungsten — which vial-shield to pick with the dispenser?

The dispenser accepts either the Saxsons Lead Vial Shield (30 mm Pb 3-part PET, NM-034) or the Tungsten Vial Shield (20 mm 3-part PET, NM-035). Lead is the cost-optimised choice with a heavier chassis; tungsten gives the same attenuation performance in a smaller, lighter chassis and is preferred where dispensing-line ergonomics or bench footprint matter. The dispenser is compatible with both — the department picks against workflow and budget preference.

Q.Which PET workflows does the dose dispenser fit?

F-18 FDG dispensing (highest throughput), Ga-68 PSMA / DOTATATE / FAPI dispensing (theranostic diagnostic pair), Lu-177 PRRT / PSMA therapy dispensing (high-activity therapy line). The tiltable geometry works for any 511 keV workflow where the technologist withdraws multiple patient doses from one bulk vial across a morning list.

Q.What accessory pairing gives the full dispensing station?

Dose dispenser + matching 3-part PET vial shield (Pb or W) + Saxsons L-Bench PET (NM-036) + Lead-Lined Fume Hood (NM-031). The four together provide the shielding + Grade A airflow + dispensing ergonomics + syringe transport chain for a full 511 keV PET dispensing line. Saxsons sources the four as an integrated package.

Q.Is this a distributor-supplied dispenser or Saxsons-manufactured?

The Dose Dispenser is a Saxsons own-brand product — designed and manufactured in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant. Integrates with the Saxsons own-brand vial shields, L-benches and fume hoods so the department gets one dispensing chain from one manufacturer with one AERB documentation dossier.

Saxsons Dose Dispenser supplier in India — Saxsons Group

Saxsons Group has supplied nuclear medicine equipment to over 1,000 Indian hospitals since 1988. Every consignment of Saxsons Dose Dispenser ships with cold-chain logistics, AERB import documentation, CDSCO registration references and a Certificate of Analysis delivered before dispatch — the paperwork your radiation-safety and procurement teams need, pre-assembled.

  • Nationwide delivery footprint — every metro and tier-2 city in India, scheduled to your treatment / procedure calendar.
  • AERB & CDSCO documentation — import licence, radiation-safety paperwork and RSO briefing pre-assembled for the audit file.
  • 40+ years in Indian oncology — long-standing supply relationships with AIIMS, Tata Memorial, and hundreds of tertiary-care centres.
  • Single point of accountability — one purchase order, one delivery contact, one after-sales team across the whole product family.
Available through Saxsons Group

The Saxsons dose dispenser, picked for the PET source-vial workflow

Contact Saxsons Healthcare Pvt. Ltd. for shielding-tier (Lead / Tungsten) + mechanism (tilt / swivel-jaw / with-rod) + vial-geometry configuration, pairing with the Saxsons vial-shield range and ISO documentation — designed and manufactured in India.