Co-57 Flood Source with lead-shielded carry case for Gamma Camera Uniformity QA
CV ≤0.9%
uniformity
INU ≤3.6%
integral non-uniformity
NEMA NU-1
2007 compliant
Co-57
272 day half-life
Pb shielded
transport case

Authorised Indian Distributor

Saxsons Group

New Delhi, India · Since 1997

SX
Nuclear Medicine NM-009 AERB Importable NEMA NU-1-2007 ANSI 42.27

Co-57 Flood Source Gamma Camera Uniformity QA

A precision Co-57 flood source producing a uniform radiation field across the gamma camera's full field of view for uniformity quality assurance per NEMA NU-1-2007. Coefficient of variation ≤0.9% — ensures your SPECT camera performs to specification between service visits.

Key Features

  • Uniform radiation field for NEMA NU-1-2007 gamma camera uniformity evaluation
  • Coefficient of Variation (CV) ≤ 0.9% — precision-manufactured uniformity
  • Integral Non-Uniformity (INU) ≤ 3.6% across full useful field of view
  • Manufactured per ANSI 42.27 sealed source standard
  • Co-57 emits 122 keV gamma — ideal for Tc-99m energy window uniformity testing
View all features

All Features

  • Uniform radiation field for NEMA NU-1-2007 gamma camera uniformity evaluation
  • Coefficient of Variation (CV) ≤ 0.9% — precision-manufactured uniformity
  • Integral Non-Uniformity (INU) ≤ 3.6% across full useful field of view
  • Manufactured per ANSI 42.27 sealed source standard
  • Co-57 emits 122 keV gamma — ideal for Tc-99m energy window uniformity testing
  • 272-day half-life — minimal activity correction for 6–12 months of use
  • Lead-shielded transport carrying case included as standard
  • NIST-traceable activity at calibration date
  • Available in sizes matching major SPECT camera head dimensions
  • Intrinsic and extrinsic uniformity measurements supported
  • Compatible with all major clinical SPECT and gamma camera platforms
  • Certificate of conformance with each source

Technical Specifications

Source radionuclide Cobalt-57 (Co-57)
Photon energy 122 keV (86%) — matched to Tc-99m energy window
Half-life 271.79 days
Uniformity (CV) ≤ 0.9% across active area
Integral non-uniformity ≤ 3.6% (NEMA NU-1-2007)
Manufacturing standard ANSI 42.27 sealed source
Calibration traceability NIST-traceable activity certificate
Sizes available Multiple — to match SPECT camera field of view
Transport shielding Lead-shielded carry case (included)
Camera compatibility All major clinical SPECT / gamma camera platforms
Usage type Intrinsic (collimator off) and extrinsic (collimator on)

Applications

Gamma camera QA — protecting image quality every day

Daily Uniformity QC

AAPM and AERB-recommended daily flood uniformity acquisition for gamma cameras. Identifies non-functioning PMT modules, crystal damage and electronic instability before patient imaging.

Weekly NEMA Uniformity

Full NEMA NU-1-2007 integral and differential uniformity measurement. Provides quantitative uniformity metrics for NABH and JCI accreditation records.

Centre of Rotation QA

Used in combination with point sources for COR measurement in SPECT systems. Correct COR calibration is essential for artefact-free SPECT reconstruction.

Energy Peaking Verification

The 122 keV energy peak closely matches the 140 keV Tc-99m window for energy resolution verification. Confirms energy discrimination performance of the crystal-PMT array.

Acceptance Testing

New SPECT camera acceptance testing per NEMA NU-1-2007. Quantitative flood uniformity data establishes the baseline for the camera's operational life.

Post-Service Baseline

Re-establish uniformity baseline after PMT replacement, crystal repair or major software updates. Confirms the camera meets specification before resuming patient imaging.

Why Co-57 Flood Source?

≤0.9% CV
Precision uniformity

Flood source non-uniformity adds directly to the camera's measured uniformity. At ≤0.9% CV, the source contribution is negligible even for the best modern SPECT detectors — you measure camera performance, not source imperfection.

272 days
Long service life

Co-57's 272-day half-life means one source covers 12+ months of daily QA with manageable activity correction. Far more cost-effective than shorter-lived alternatives that require replacement every 2–3 months.

122 keV
Tc-99m surrogate

122 keV is close enough to 140 keV to use in the Tc-99m energy window for uniformity testing — yet Co-57's long half-life makes it practical for routine QA. No need to use patient-dose Tc-99m generator eluate for daily camera checks.

Catalogs & Resources

Manufacturer product page. Contact Saxsons for AERB documentation, camera-specific sizing and pricing.

Co-57 Flood Source

More for this product

Each card opens a focused post for a specific specialty — peer-reviewed evidence and clinical workflow, written for the persona you select.

Available through Saxsons Group

Maintain your SPECT camera at peak performance

Contact Saxsons Group for Co-57 flood sources, sizing for your camera model and AERB documentation across India.