Ge-68 Line Source for PET Scanner Normalization — sealed cylindrical sources with shielded transport canister
Ge-68/Ga-68
generator pair
±5%
uniformity
Stainless
steel sealed
271 day
half-life
2D + 3D
normalization

Authorised Indian Distributor

Saxsons Group

New Delhi, India · Since 1997

SX
Nuclear Medicine NM-011 AERB Importable PET Normalization 271-day half-life

Ge-68 Line Source PET / PET-CT Normalization

Precision Ge-68/Ga-68 cylindrical line sources for 2D and 3D normalization of PET and PET-CT scanners. Double-layer stainless steel, argon-welded sealed ends, ±5% uniformity — providing long-lived, stable normalization performance across the PET scanner's clinical life.

Key Features

  • Double-layer stainless steel tube construction — maximum sealed source integrity
  • Argon-welded sealed ends — zero activity leakage risk
  • Uniformly filled radioactive element — ±5% uniformity along entire length
  • QC verified with 5mm scanning intervals across full source length
  • Laser-marked source information: product code, isotope, activity, serial number, date
View all features

All Features

  • Double-layer stainless steel tube construction — maximum sealed source integrity
  • Argon-welded sealed ends — zero activity leakage risk
  • Uniformly filled radioactive element — ±5% uniformity along entire length
  • QC verified with 5mm scanning intervals across full source length
  • Laser-marked source information: product code, isotope, activity, serial number, date
  • Compatible with 2D and 3D PET and PET-CT normalization protocols
  • QC results available on request with PET-CT scanner verification images
  • 271-day half-life — predictable activity decay for multi-year normalization use
  • Suitable for all major clinical PET and PET-CT scanner platforms
  • AERB-compliant sealed source with transport documentation
  • Full traceability via laser marking — no labelling loss during handling
  • Available in sizes for different scanner bore and normalization geometries

Technical Specifications

Source radionuclide Germanium-68 (Ge-68) / Gallium-68 (Ga-68) — secular equilibrium
Half-life 270.95 days (Ge-68 parent)
Photon emission 511 keV annihilation photons (from Ga-68 daughter positron)
Tube material Double-layer stainless steel
End closure Argon welding — hermetically sealed
Uniformity ±5% along source length (QC at 5mm intervals)
Traceability marking Laser-marked: product code, isotope, activity, S/N, date
Verification PET-CT scanner image QC; test results available on request
Compatible systems All major clinical PET / PET-CT scanner platforms
Applications 2D normalization; 3D normalization; PET scanner QA imaging
AERB classification Sealed source; AERB licence and import documentation provided

Applications

PET normalization — the calibration behind every quantitative PET scan

PET Scanner 3D Normalization

3D PET normalization uses line sources rotated around the scanner FOV to characterise detector sensitivity. Ge-68 line sources deliver stable, reproducible 511 keV reference counts for accurate normalization files.

2D PET Normalization

Older 2D PET systems requiring septa-based normalization use line source rotation. Ge-68 long half-life means one source set survives scanner software upgrades and detector map updates.

PET-CT Scanner QA Imaging

Cylindrical phantom imaging for PET uniformity, sensitivity and spatial resolution QA. Documented scanner performance supports AERB inspection compliance and NABH accreditation.

Sensitivity and Resolution Testing

NEMA NU-2 sensitivity and resolution measurements using line sources in specified phantoms. Establishes baseline PET performance for acceptance testing and post-service verification.

Dose Calibrator Verification

Ge-68 point sources verify dose calibrator Ge-68/Ga-68 calibration factor, essential for PET departments dispensing Ga-68 radiopharmaceuticals and needing NIST-traceable dose calibration.

Scanner Upgrade Validation

Post-upgrade normalization re-acquisition with the same Ge-68 source provides a consistent reference for before-after comparison, validating the upgrade did not degrade scanner performance.

Why Ge-68 Line Source?

±5%
Uniform along length

The source activity is verified at 5mm intervals along the full length before dispatch. Non-uniformity in the line source propagates into the normalization file and degrades PET image quality — ±5% uniformity is the accepted clinical standard.

271 days
Multi-year service

Ge-68's 271-day half-life allows the same source to be used for 2–3 years with predictable activity correction. Contrast to F-18 or Ga-68 sources that decay in hours — Ge-68 is the only practical choice for routine normalization.

Sealed
Zero leakage risk

Double-wall stainless steel with argon-welded ends and regular leak test documentation. A sealed Ge-68 source handled correctly in a clinical environment presents no contamination hazard and no wipe test failures at AERB inspection.

Catalogs & Resources

Manufacturer product page. Contact Saxsons for AERB import licensing, scanner-specific sizing and pricing.