MUCHA Nova multi-channel gamma analyser — shielded chassis with touchscreen workflow
Multi-channel
gamma analyser (MCA)
NaI(Tl) / HPGe
standard + HR chassis
Auto nuclide ID
comprehensive library
Touchscreen
dialog-guided workflow
SQL database
inspection-ready records

Authorised Indian Distributor

Saxsons Group

New Delhi, India · Since 1997

SX
Nuclear Medicine NM-008 AERB Importable Radionuclidic purity Nuclide library auto-ID 21 CFR Part 11 audit

MUCHA Nova Multi-Channel Gamma Analyser for Nuclide Identification + Radionuclidic Purity

Multi-channel gamma analyser for radionuclide identification and radionuclidic-purity testing. NaI(Tl) standard chassis or HPGe high-resolution chassis (MUCHA Nova HR). Touchscreen-driven hot-lab workflow with automatic energy calibration on startup. Comprehensive nuclide library covers diagnostic and therapeutic radionuclides. SQL audit-trail database records every spectrum, every operator signature, every release decision — 21 CFR Part 11 compliant.

Key Features

  • Multi-channel analyser optimised for the radiopharmacy radionuclide-identification workflow
  • NaI(Tl) scintillation standard chassis covers the daily release programme; HPGe high-resolution chassis (MUCHA Nova HR) resolves close-lying lines
  • Automatic energy calibration on instrument startup — ready to measure on first sample
  • Comprehensive radionuclide library covers diagnostic + therapeutic isotopes (Tc-99m, F-18, Ga-68, Lu-177, I-131, Cu-64, Mo-99, Ge-68 and more)
  • Automatic peak matching against the library; PASS / FAIL on radionuclidic-purity threshold returned per-batch
View all features

All Features

  • Multi-channel analyser optimised for the radiopharmacy radionuclide-identification workflow
  • NaI(Tl) scintillation standard chassis covers the daily release programme; HPGe high-resolution chassis (MUCHA Nova HR) resolves close-lying lines
  • Automatic energy calibration on instrument startup — ready to measure on first sample
  • Comprehensive radionuclide library covers diagnostic + therapeutic isotopes (Tc-99m, F-18, Ga-68, Lu-177, I-131, Cu-64, Mo-99, Ge-68 and more)
  • Automatic peak matching against the library; PASS / FAIL on radionuclidic-purity threshold returned per-batch
  • Live spectrum display during acquisition — flag unexpected lines before the run completes
  • Touchscreen dialog-guided interface; minimal operator training to release-grade routine work
  • Configurable low / medium / high energy ranges per measurement — same chassis covers SPECT and PET isotopes
  • Background spectrum accumulation and automatic subtraction maintain limit-of-detection over service life
  • SQL audit-trail database stores every spectrum, operator signature, calibration record and release decision; 21 CFR Part 11 compliant
  • AERB hot-lab QC fit: instrument operates inside the radiopharmacy licence; release-record format meets AERB inspection expectations
  • Documentation: datasheet, IQ / OQ / PQ protocols, calibration certificate, 21 CFR Part 11 validation evidence

Technical Specifications

Analyser type Multi-channel analyser (MCA) for gamma spectrometry
Detector chassis NaI(Tl) scintillation (standard); HPGe (MUCHA Nova HR high-resolution variant)
Energy ranges Low, medium and high — operator-selectable per measurement
Nuclide library Comprehensive — diagnostic and therapeutic radionuclides; expandable for IIP work
Identification method Automatic peak matching against the library; radionuclidic-purity threshold check
Energy calibration Automatic on startup; multi-source protocols supported (Cs-137 / Co-57 / Co-60)
Background management Automatic accumulation and subtraction; periodic background-update protocol
Interface Touchscreen; dialog-guided workflow for hot-lab operator
Data storage SQL audit-trail database; spectrum file export; printer output for batch record
Shielding (HR chassis) Enhanced lead shielding — lowest achievable background for HPGe high-resolution work
Compliance framework AERB hot-lab QC, Eur.Ph. radionuclidic-purity monographs, USP <823>, 21 CFR Part 11
Validation IQ / OQ / PQ protocols supplied; site PQ scheduled during install

Applications

Know your isotope before it reaches the patient — and document it for the inspector

Radionuclidic-purity release

Mandatory per-batch QC for diagnostic and therapeutic radiopharmaceuticals. The MCA spectrum confirms the intended radionuclide and rules out generator-breakthrough or cyclotron-by-product contamination. Eur.Ph. monographs cite gamma-spectrometric methods explicitly.

Mo-99 breakthrough check

Generator-eluate QC — distinguishes the 140 keV Tc-99m line from 740 / 780 keV Mo-99 breakthrough lines in a single gamma spectrum. Faster and more sensitive than dose-calibrator shielded-attenuator methods alone.

Ge-68 breakthrough check

Ge-68 / Ga-68 generator eluate QC. The delayed-spectrum check after Ga-68 decay catches residual Ge-68 against the Eur.Ph. breakthrough limit (< 0.001 % at expiry).

Lu-177 nuclide identity

Theranostic-batch QC — confirms the 113 / 208 keV Lu-177 doublet and checks for the 228 keV Lu-177m peak that distinguishes carrier-added from n.c.a. supply. Pairs with the radio-TLC %RCP on the same batch record.

Cyclotron target analysis

Quantifies radionuclidic impurities in cyclotron-produced F-18, Ga-68 and Cu-64 — identifies co-produced isotopes and confirms target-material activation profile. The live spectrum display flags unexpected co-productions early in the count.

Waste characterisation + audit

Identify and quantify radionuclides in the hot-lab waste stream for decay-in-storage planning. The same nuclide library covers environmental monitoring, sealed-source audit and inspection-prep gamma surveys.

Why MUCHA Nova?

Auto ID
Comprehensive nuclide library

Automatic peak matching against a comprehensive library — no manual peak assignment. The operator sees PASS / FAIL on the radionuclidic-purity threshold and the library-matched primary isotope; the inspector sees the same on the release record.

Live view
Real-time spectrum build

The spectrum builds in real time on the touchscreen during acquisition. Unexpected peaks — cyclotron co-productions, generator-breakthrough events, contamination from adjacent activity — show up before the count completes; the operator can intervene before reporting.

SQL audit
Inspection-ready release records

Every spectrum, every operator signature, every calibration record stored in the SQL audit-trail database. The AERB inspector reads the same release record off the database that the radiopharmacist signed at release — no parallel paper log to reconcile.

MUCHA Nova

More for this product

Each card opens a focused post for a specific specialty — peer-reviewed evidence and clinical workflow, written for the persona you select.

Available through Saxsons Group

Gold-standard gamma spectrometry for the radionuclidic-purity gate

Contact Saxsons Group for MUCHA Nova supply (NaI / HPGe HR chassis), India install scheduling, IQ / OQ / PQ documentation and AERB-aligned operator training.