Saxsons Group — India's trusted nuclear medicine, radiotherapy, oncosurgery, dosimetry and cyclotron supplier since 1986
📖 Free full textPeer-ReviewedPubMedResearch ArticleQA & dosimetryJournal of applied clinical medical physics · 2026

Assessment of rotational dose perturbations in SBRT: A radiomic-dosiomic predictive model based on the structural similarity index measure.

Qi R, Sun J, Mu T, Shi H, Zhang J, Dai X.

Abstract

BackgroundStereotactic body radiation therapy (SBRT) delivers ablative doses with high precision but is sensitive to target motion, especially rotational errors. Conventional dose metrics (dose difference (DD), distance-to-agreement (DTA), gamma index) show limited sensitivity. The structural similarity index measure (SSIM), combined with radiomics and dosiomics, may better characterize complex dose perturbations.PurposeTo evaluate the impact of rotational errors on SBRT dose distributions using SSIM and to develop predictive models integrating radiomic-dosiomic features.Materials and methodsSixty-nine clinically validated CyberKnife treatment plans were retrospectively analyzed. In a two-stage phantom experiment, dose distributions were measured under simulated discrete and non-discrete rotational errors (ranging from 1.5 to 4.5 degrees), verified by the CyberKnife System Plan QA module. Of the total dose images acquired, 405 datasets (364 from the first stage and 41 from the second stage) passed rigorous quality control. SSIM and gamma passing rates (at 1%/1 mm,1.5%/1.5 mm and 2%/2 mm criteria) were calculated to evaluate their relative sensitivity. Radiomic and dosiomic features were extracted, followed by feature selection using eXtreme Gradient Boosting (XGBoost) with Shapley Additive Explanations (SHAP). Predictive models were optimized via automated machine learning. Performance was assessed with coefficient of determination (R²), mean absolute error (MAE), root mean -squared error (RMSE), and median absolute error (MedAE).ResultsRotational errors significantly decreased SSIM, showing robust negative correlations with rotation angles across all single-directional inputs (r ranging from -0.632 to -0.747, all p 0.05), SSIM retained a statistically significant negative correlation (p ConclusionsSSIM is a sensitive, structure-aware metric for evaluating rotational dose perturbations in SBRT, particularly surpassing conventional metrics in detecting complex multi-directional errors. Integrating radiomic-dosiomic modeling enhances predictive accuracy and robustness, providing a reliable tool for individualized and automated radiotherapy quality assurance (QA).

Identifiers

Radar topics

Related in the same topic