Feasibility of prostate offline adaptive radiation therapy using iterative reconstructed CBCT to optimize the ART workflow.

Vicedo González MA, García Hernández MT, Alcaraz Lozano ML, Pardos RG, Rovira Escutia JJ, Meseguer DP (+3 more)

Abstract

Adaptive Radiotherapy (ART) updates treatment plans based on newly acquired anatomical information to maintain dosimetric accuracy. Image-Guided Radiotherapy (IGRT) is essential for detecting anatomical changes and guiding replanning decisions. This study evaluates the feasibility of using iterative Cone Beam CT (iCBCT) acquired on a TrueBeam system as a reference image dataset for dose calculation and offline ART in prostate radiotherapy. The approach avoids additional simulation CTs and reduces uncertainties from deformable image registration (DIR). A CIRS electron-density phantom was embedded in solid-water slabs and surrounded by bolus to simulate varying patient-scanned volumes. HU-density calibration curves were generated for a standard prostate patient volume (sHU-density) and volume-specific conditions (vHU-density) and imported into Eclipse planning system along with the planning (pCT) calibration curve (pHU-density). Twenty prostate VMAT plans were retrospectively recalculated on registered iCBCT images using these curves. Dosimetric parameters (Dmean, D98%, D2%) and 3D gamma analysis (1%/1 mm, 10% threshold) assessed dose differences. An Alderson Rando phantom study was used to compared pCT-based (pHU-density) and iCBCT-based (sHU-density) calculations. HU-density curves were stable across scanned volumes, particularly for soft tissues. Dosimetric differences between sHU-density and vHU-density curves were 99%. Using the pHU-density curve on iCBCT introduced 1% systematic dose deviations. Phantom measurements confirmed strong agreement between pCT- and iCBCT-based calculations using an iCBCT-specific calibration curve. iCBCT with a dedicated HU-density calibration curve provides dose calculation accuracy comparable to planning CT, supporting reliable offline ART in prostate radiotherapy.

Identifiers

Relevant Saxsons product

Related in the same topic