Saxsons Group — India's trusted nuclear medicine, radiotherapy, oncosurgery, dosimetry and cyclotron supplier since 1986
SortApplication
QA & dosimetryPeer-ReviewedPubMedPractical radiation oncology · 2026

Medical Physicist-Patient Consultation Enhances the Reproducibility of Treatment Delivery in Radiation Therapy for Breast Cancer: An EPID-Based In Vivo Transit Dosimetry Study.

Marino C, Bonanno E, Borzì GR, Cavalli N et al.

PurposePrevious studies have suggested that direct interaction between medical physicists and patients may improve patient understanding of radiation therapy and reduce treatment-related anxiety. Howe…

QA & dosimetryRadiation safety📖 Free full textPeer-ReviewedPubMedPhysica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026

Impact of phantom design on fetal radiation exposure assessment in pregnant women undergoing head and neck 6MV photon radiotherapy.

Edouard M, Martin A, Chea M, Jenny C et al.

PurposeThis study investigates phantom-based methods for fetal radiation exposure assessment in photon external beam radiotherapy for a pregnant patient, using representative uterine locations as a co…

QA & dosimetry📖 Free full textPeer-ReviewedOpenAlexBrazilian Journal of Radiation Sciences · 2026

Response of a Commercial MOSFET to Clinical Photon and Electron Beams Used in Radiotherapy

Luiz Flávio Kalil Telles, L. M. Maria, Divanízia N. Souza, Luiz Antonio Pereira dos et al.

One type of dosimeter used in radiotherapy is the metal-oxide-semiconductor field-effect transistor (MOSFET), which is widely employed in in vivo dosimetry. This study investigated the response of a c…

QA & dosimetryPeer-ReviewedPubMedThe British journal of radiology · 2026

Results of an international survey of SunCHECK Patient users: consensus and benchmark data for plan verification, pre-treatment quality assurance and in vivo dosimetry tolerances.

Haughey A, Biggar R, Caines R, Moloney S et al.

ObjectivesElectronic portal imaging devices (EPID) are well suited to radiotherapy in-vivo dosimetry (IVD), but limited guidance remains a barrier to routine clinical use. This SunCHECK (Sun Nuclear C…

QA & dosimetryPeer-ReviewedPubMedRadiological physics and technology · 2026

In vivo dosimetry of cardiac implantable electronic devices with a radiophotoluminescent glass dosimeter in patients undergoing radiotherapy.

Mikasa S, Okamoto H, Miura Y, Watanabe Y et al.

We aimed to establish and evaluate a method for measuring the cardiac implantable electronic devices (CIEDs) dose of radiotherapy patients using radiophotoluminescence glass dosimeters (RPLDs). Thirty…

QA & dosimetry📖 Free full textPeer-ReviewedPubMedPhysics and imaging in radiation oncology · 2026

In vivo dosimetry using an electronic portal imaging device for pediatric myeloablative Total body irradiation with volumetric modulated arc therapy.

Greco F, Galetto M, Vaccaro M, De Spirito M et al.

Background and purposeVolumetric Modulated Arc Therapy (VMAT) has enabled highly conformal Total Body Irradiation (TBI), improving dose homogeneity and sparing of organs-of-interest. However, the incr…

QA & dosimetryRadiation safetyPeer-ReviewedPubMedPhysica medica · 2026

Fetal dose assessment in radiotherapy: A systematic review and results of survey on assessment tools and methods, dose ranges, optimization strategies and imaging dose.

Huet C, Belchior A, Bassinet C, Sa AC et al.

PurposeThis study aimed to identify the methods currently used to evaluate fetal dose in pregnant patients undergoing radiotherapy, the strategies implemented to optimize fetal exposure, and the fetal…

TherapeuticQA & dosimetry📖 Free full textPeer-ReviewedPubMedJournal of applied clinical medical physics · 2026

Experimental evaluation of an intraoperative-imaging based workflow for electron beam radiotherapy of pancreatic cancer using in situ dosimetry.

Iliaskou C, Gainey M, Kollefrath M, Kuhn S et al.

PurposeThe aim of this study is to perform an experimental evaluation of an imaging-based intraoperative electron beam radiotherapy (IOERT) and in vivo dose verification workflow for pancreatic cancer…

QA & dosimetryPeer-ReviewedPubMedRadiological physics and technology · 2026

Retrospective analysis on large-scale in-vivo dosimetric verification of total body irradiation using helical tomotherapy with optically stimulated luminescence dosimeters.

Singh S, Dipesh, Sen S, Singh AK et al.

To perform a large-scale clinical evaluation of OSLD-based in-vivo dosimetry for helical TomoTherapy-based total body irradiation, focusing on patient thickness, anatomical region, junction stability,…

QA & dosimetryRadiation safety📖 Free full textPeer-ReviewedPubMedTechnical innovations & patient support in radiation oncology · 2026

A case report of radiotherapy for head and neck cancer in a pregnant woman: dosimetric optimization and in vivo dosimetry.

Martin A, Thibouw D, Delcoudert L, Aubignac L et al.

BackgroundRadiotherapy during pregnancy is a rare and ethically complex requiring careful management of fetal exposure. Although peripheral doses from head and neck radiotherapy are typically low, fet…

QA & dosimetry📖 Free full textPeer-ReviewedPubMedQuantitative imaging in medicine and surgery · 2026

Characterization of a novel large-area electronic portal imaging device system for a ring-shaped HalosTx linear accelerator in radiotherapy quality assurance.

Dai G, Gao D, Xiao Q, Song Y et al.

BackgroundElectronic portal imaging device (EPID)-based in vivo dosimetry (IVD) has attracted considerable interest in recent years. Nevertheless, the limited detection area of conventional EPID syste…

QA & dosimetry📖 Free full textPeer-ReviewedPubMedInternational journal of radiation oncology, biology, physics · 2026

Clinical Pilot Study of Ionizing Radiation Acoustic Imaging for Real-Time Visualization of Radiation Therapy Dose Delivery in Cancer Patients.

Cuneo KC, Zhang W, Litzenberg D, Huang Y et al.

PurposeThis study aimed to evaluate the feasibility of using ionizing radiation acoustic imaging (iRAI) to map the delivered dose in patients receiving radiation therapy (RT) with various treatment te…

TherapeuticQA & dosimetry📖 Free full textCited 1×Peer-ReviewedPubMedJournal of applied clinical medical physics · 2025

Impact of amalgam dental filling on radiotherapy of head and neck cancer: In vivo dosimetry and dose calculation using AAA and Acuros algorithms.

Fodor E, Varga Z, Kelemen G, Oláh J et al.

IntroductionDental restorations using high-density materials can cause inaccuracies in target and organ-at-risk (OAR) delineation and dose calculations during radiotherapy. These materials, such as am…

QA & dosimetry📖 Free full textCited 2×Peer-ReviewedPubMedJournal of applied clinical medical physics · 2025

Deep learning-based 3D dose reconstruction for intensity modulated radiation therapy using electronic portal imaging devices.

Yang D, Fan J, Wenliang Y, Wang J et al.

Background and purposeElectronic portal imaging devices (EPIDs) have been used as an in vivo dosimetry method to identify treatment discrepancies by comparing planned and predicted 3D dose. The purpos…

QA & dosimetryPeer-ReviewedPubMedOral surgery, oral medicine, oral pathology and oral radiology · 2026

In vivo dosimetry in head and neck cancer radiotherapy patients using an intraoral stent: prospective cohort.

Alves LDB, Menezes ACDS, Marin AV, Viegas CCB et al.

ObjectivesTo evaluate the radiation dose in the oral cavity structures (through in vivo dosimetry and treatment planning system) of head and neck cancer patients; and secondarily, evaluate sialometry …

TherapeuticQA & dosimetryCited 1×Peer-ReviewedPubMedZeitschrift fur medizinische Physik · 2025

Development of a TLD-100 based set up for in vivo dosimetry in Intraoperative Electron Beam Radiation Therapy (IOERT): an experimental and clinical evaluation.

Iliaskou C, Gainey M, Thomann B, Kollefrath M et al.

PurposeThis study presents an in-house developed set-up enabling the placement of multiple TLDs over the target region, for in vivo dosimetry in intraoperative electron beam radiotherapy (IOERT).Metho…

QA & dosimetry📖 Free full textCited 4×Peer-ReviewedPubMedJournal of applied clinical medical physics · 2025

Clinical validation of myOSLchip: A beryllium oxide optically stimulated luminescent dosimeter (OSLD) system in radiotherapy dosimetry.

Davis H, Siebers JV, Wijesooriya K, Mistro M.

In radiation oncology, inter-fractional dosimetry using optically stimulated luminescent detectors (OSLDs) ensures accurate plan delivery and patient safety. RadPro International GmbH's myOLSchip syst…

QA & dosimetryTherapeutic📖 Free full textCited 8×Peer-ReviewedPubMedJournal of applied clinical medical physics · 2025

Machine stability and dosimetry for ultra-high dose rate FLASH radiotherapy human clinical protocol.

Gonçalves Jorge P, Geyer R, Kinj R, Schiappacasse L et al.

BackgroundThe FLASH effect, induced by ultra-high dose rate (UHDR) irradiations, offers the potential to spare normal tissue while effectively treating tumors. It is important to achieve precise and a…

Therapeutic📖 Free full textPeer-ReviewedPubMedJournal of contemporary brachytherapy · 2025

Assessment of rectal dose with thermoluminescent in vivo dosimetry in high-dose-rate cobalt-60 intracavitary brachytherapy for cervical cancer: A two-arm cohort study using orthogonal images planning.

Mlawa OM, Ngaile JE, Chaurasia PP, Amasi AI.

PurposeHigh-dose-rate intracavitary brachytherapy delivers high radiation doses to tumors while minimizing exposure to surrounding normal cells. However, inappropriate administration can lead to radia…

QA & dosimetryPeer-ReviewedPubMedRadiation and environmental biophysics · 2025

Commissioning and performance assessment of diodes and MOSFETs in in-vivo dosimetry for external beam radiation therapy.

Al Kharusi O, Al Mamari R, Al Hosni B, Al Amri I et al.

The precision of radiation therapy treatment depends on several calibration and quality assurance processes. In-vivo dosimetry (IVD) is used in external beam radiotherapy to evaluate the delivered ver…

QA & dosimetry📖 Free full textCited 5×Peer-ReviewedPubMedJournal of applied clinical medical physics · 2025

Characterization, commissioning, and clinical evaluation of a commercial BeO optically stimulated luminescence (OSL) system.

Kowalski JP, Erickson BG, Wu Q, Li X et al.

This article investigates the performance of a commercial BeO optically stimulated luminescent (OSL) dosimetry system (myOSLchip, RadPro GmbH International, Remscheid, Germany) through the application…

TherapeuticQA & dosimetry📖 Free full textCited 1×Peer-ReviewedPubMedMedical physics · 2025

In vivo dosimetry for proton therapy: A Monte Carlo study of the Gadolinium spectral response throughout the course of treatment.

Brás M, Freitas H, Gonçalves P, Seco J.

BackgroundIn proton radiotherapy, the steep dose deposition profile near the end of the proton's track, the Bragg peak, ensures a more conformed deposition of dose to the tumor region when compared wi…

TherapeuticQA & dosimetryPeer-ReviewedPubMedJournal of medical imaging and radiation sciences · 2024

In vivo dose measurements for tangential field-in-field ultra-hypofractionated breast radiotherapy.

Abdelmajeed M, Attalla EM, Elshemey WM, Elfiky AA et al.

IntroductionUltra-hypofractionated radiotherapy (UHF-RT) mandates more accuracy in each part of the treatment cycle to maximize cure rates and minimize toxicities. In vivo dosimetry is a direct method…

QA & dosimetry📖 Free full textCited 7×Peer-ReviewedPubMedJournal of synchrotron radiation · 2023

Monocrystalline diamond detector for online monitoring during synchrotron microbeam radiotherapy.

di Franco F, Rosuel N, Gallin-Martel L, Gallin-Martel ML et al.

Microbeam radiation therapy (MRT) is a radiotherapy technique combining spatial fractionation of the dose distribution on a micrometric scale, X-rays in the 50-500 keV range and dose rates up to 16 × …

TherapeuticQA & dosimetry📖 Free full textPeer-ReviewedPubMedAsian Pacific journal of cancer prevention · 2023

Patient Dose Analysis Using GafchromicTM EBT3 Film: A Retrospective Study with a Four Dual-Field Technique in Total Skin Electron Therapy.

Sundaramoorthy D, Chandrasekaran A.

ObjectiveThe Six dual-field is the most commonly used treatment technique in total skin electron therapy (TSET). Because of the prolonged treatment period, the patient may experience discomfort, and r…

QA & dosimetry📖 Free full textCited 1×Peer-ReviewedPubMedJournal of applied clinical medical physics · 2023

The application of gradient dose segmented analysis of in-vivo EPID images for patients undergoing VMAT in a resource-constrained environment.

van Reenen CJ, Trauernicht CJ, Bojechko C.

The gamma analysis metric is a commonly used metric for VMAT plan evaluation. The major drawback of this is the lack of correlation between gamma passing rates and DVH values. The novel GDSAmean metri…

QA & dosimetry📖 Free full textCited 3×Peer-ReviewedPubMedJournal of applied clinical medical physics · 2023

Selective de-implementation of routine in vivo dosimetry.

Mao SPH, Han-Oh S, Moore J, Huang E et al.

As cone-beam computed tomography (CBCT) has become the localization method for a majority of cases, the indications for diode-based confirmation of accurate patient set-up and treatment are now limite…

QA & dosimetry📖 Free full textCited 7×Peer-ReviewedPubMedPhysics and imaging in radiation oncology · 2023

Assessing the impact of adaptations to the clinical workflow in radiotherapy using transit in vivo dosimetry.

Bossuyt E, Nevens D, Weytjens R, Taieb Mokaddem A et al.

Background and purposeCurrently in-vivo dosimetry (IVD) is primarily used to identify individual patient errors in radiotherapy. This study investigated possible correlations of observed trends in tra…

QA & dosimetry📖 Free full textCited 40×Peer-ReviewedPubMedPhysics and imaging in radiation oncology · 2020

Evaluation of automated pre-treatment and transit in-vivo dosimetry in radiotherapy using empirically determined parameters.

Bossuyt E, Weytjens R, Nevens D, De Vos S et al.

Background and purposeFirst reports on clinical use of commercially automated systems for Electronic Portal Imaging Device (EPID)-based dosimetry in radiotherapy showed the capability to detect import…

QA & dosimetry📖 Free full textCited 67×Peer-ReviewedPubMedPhysics and imaging in radiation oncology · 2020

In vivo dosimetry in external beam photon radiotherapy: Requirements and future directions for research, development, and clinical practice.

Olaciregui-Ruiz I, Beddar S, Greer P, Jornet N et al.

External beam radiotherapy with photon beams is a highly accurate treatment modality, but requires extensive quality assurance programs to confirm that radiation therapy will be or was administered ap…

QA & dosimetry📖 Free full textCited 12×Peer-ReviewedPubMedJournal of applied clinical medical physics · 2019

Optimization of skin dose using in-vivo MOSFET dose measurements in bolus/non-bolus fraction ratio: A VMAT and a 3DCRT study.

Dias AG, Pinto DFS, Borges MF, Pereira MH et al.

In-phantom and in-vivo three dimensional conformal radiation therapy (3DCRT) and volumetric modulated arc therapy (VMAT) skin doses, measured with and without bolus in a female anthropomorphic phantom…

QA & dosimetry📖 Free full textCited 41×Peer-ReviewedPubMedJournal of applied clinical medical physics · 2019

EPID-based in vivo dosimetry using Dosimetry Check™: Overview and clinical experience in a 5-yr study including breast, lung, prostate, and head and neck cancer patients.

Nailon WH, Welsh D, McDonald K, Burns D et al.

BackgroundIndependent verification of the dose delivered by complex radiotherapy can be performed by electronic portal imaging device (EPID) dosimetry. This paper presents 5-yr EPID in vivo dosimetry …

Showing the 60 most recent of 98 papers in this topic.Browse every paper →