QA & dosimetryPeer-ReviewedPubMedApplied radiation and isotopes · 2026

Validation of a 3D-printed anthropomorphic eye phantom for quality assurance in external beam radiotherapy using TLD and radiochromic film.

Fidelis ALE, Batista DVS, Cardoso SC, da Rosa LAR.

External beam radiation therapy (EBRT) is widely used for uveal melanoma to preserve the eye and achieve effective tumor control. However, late side effects remain a concern, reinforcing the need for …

QA & dosimetryPeer-ReviewedPubMedJournal of biomedical physics & engineering · 2026

Comparison of the Measurement Uncertainty of Thermoluminescence Dosimeters (TLD-100 and GR-200) in Clinical Radiotherapy Energies.

Sadeghi B, Pur Imani R, Kiani H, Bayatiani MR et al.

BackgroundAccurate determination of individual radiation doses is critical in dosimetry, and international standards emphasize the importance of reporting measurement uncertainties. Neglecting measure…

QA & dosimetry📖 Free full textPeer-ReviewedOpenAlexScientific Reports · 2026

Structural & Thermoluminescence properties of bio−engineered ZnTiO3 nanostructures via Hoodia gordonii ethanolic extract & their dosimetric performances

N. Sintwa, T. E. Talane, P. Thokwane, D. V. Mlotswa et al.

This study reports the bioengineering of zinc titanate (ZnTiO 3 ) and its possible dosimetric efficacy. The bio-inspired synthesis of the rhombohedral ZnTiO 3 phase via Hoodia gordonii natural extract…

Radiation safety📖 Free full textPeer-ReviewedPubMedRadiation protection dosimetry · 2026

Spatial distribution of X-ray attenuation in a full-face shield: a multipoint in vivo study in interventional cardiology.

Bonutti F, Favaretto E, Alvarado AGG, Rosso V et al.

Occupational radiation exposure remains a critical concern in interventional cardiology, particularly regarding brain and ocular protection. This study evaluates the protective efficacy of a 0.12 mmPb…

Radiation safety📖 Free full textPeer-ReviewedPubMedRadiation protection dosimetry · 2026

Assessment of occupational radiation exposure among radiology workers in Ghana using cytogenetic biomarkers and thermoluminescent dosimetry.

Owusu J, Achel DG, Kpeglo DO, Agbenyegah S.

Occupational exposure to ionizing radiation remains an important radiation protection concern among radiology workers. This study assessed cytogenetic damage among radiology workers in Ghana using the…

Radiation safety📖 Free full textPeer-ReviewedPubMedRadiation protection dosimetry · 2026

Occupational effective doses for regional and university hospitals in Albania (2021-2025): optimization and statistical analysis.

Gega E, Bylyku E, Spahiu E, Daci B et al.

The Institute of Applied Nuclear Physics conducts periodic monitoring of doses for occupationally exposed workers in Albania. This is the first study in Albania that includes all regional and universi…

QA & dosimetryPeer-ReviewedPubMedApplied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026

Influence of precursor purity on the low-dose TL and OSL response of flux-grown pure α-Al₂O₃.

Rodrigues CMC, Saraiva JG, Alves LC, Rodrigues AL et al.

Luminescence dosimetry continues to advance through efforts to improve detector sensitivity, stability, and cost-effectiveness. Within this scope, Al2O3 crystals were produced by the flux-growth metho…

Radiation safety📖 Free full textPeer-ReviewedPubMedJournal of the Society for Cardiovascular Angiography & Interventions · 2026

Randomized Evaluation of a Textile-Based Enhanced Radiation Protection Device Versus Control Shielding in the Cardiac Catheterization Laboratory.

Angerås O, Jonasson PI, Dworeck C, Friberg G et al.

BackgroundOccupational radiation exposure remains an inherent risk in cardiac catheterization laboratories. Conventional radiation protection relies on ceiling- and table-mounted shields combined with…

Radiation safetyPeer-ReviewedPubMedRadiation protection dosimetry · 2026

External radiation exposure of turtles and soil biota in Ramsar high natural background radiation area: experimental dosimetry supported by Monte Carlo modeling.

Sina S, Karimipourfard M, Alizadeh S, Heidarinia M et al.

High natural background radiation areas (HNBRAs) can impose elevated external exposure on non-human biota, yet organism-relevant dose characterization remains limited for many extreme environments. He…

Radiation safetyPeer-ReviewedPubMedPhysica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026

Measurement- and simulation-based evaluation and optimization of fetal radiation exposure for fluoroscopy-guided interventions demonstrated for a splenic artery aneurysm.

Eggimann HJ, Alejandre-Lafont E, von Allmen RS, Binder J et al.

IntroductionA splenic artery aneurysm (SAA) during pregnancy poses a potentially life-threatening risk to patients and is challenging to treat. One treatment option is fluoroscopy-guided embolization,…

QA & dosimetryPeer-ReviewedPubMedRadiation and environmental biophysics · 2026

Towards a phantom-based quantitative assessment of dose reduction and image-quality trade-offs in half- and full-rotation dental CBCT protocols: a thermoluminescent dosimetry approach with clinical insight.

Amasya H, Günay O, Kesmezacar FF, Akdoğan ET et al.

This study aimed to compare full- (360°) and half-rotation (180°) dental cone-beam computed tomography (CBCT) protocols in terms of effective dose (ED) and quantitative image quality for the maxilla a…

Radiation safetyPeer-ReviewedPubMedJournal of radiological protection · 2026

Direct and indirect assessment: comparison of different methods to estimate staff equivalent dose to the lens during different interventional procedures.

Fedeli L, Magistrelli A, Vaiano A, Betti M et al.

The reduction of the annual equivalent dose limit to the lens of the eye from 150 to 20 mSv has increased the need for reliable assessment of occupational eye lens exposure, particularly in interventi…

QA & dosimetryPeer-ReviewedPubMedEuropean journal of radiology · 2026

Dose optimization for pediatric chest CT: a comparative study of energy-integrating and photon-counting detector CT using 70 kV and 100 kV protocols with tin filtration regarding image quality and dose exposure.

Kunert P, Weis M, Schlattl H, Schoenberg SO et al.

ObjectivePediatric thoracic imaging requires radiation dose optimization. Common strategies include protocols with low (70 kV) or medium tube voltages (100 kV) with tin filtration (100Sn). Photon-Coun…

TherapeuticQA & dosimetry📖 Free full textPeer-ReviewedPubMedJournal of applied clinical medical physics · 2026

Experimental evaluation of an intraoperative-imaging based workflow for electron beam radiotherapy of pancreatic cancer using in situ dosimetry.

Iliaskou C, Gainey M, Kollefrath M, Kuhn S et al.

PurposeThe aim of this study is to perform an experimental evaluation of an imaging-based intraoperative electron beam radiotherapy (IOERT) and in vivo dose verification workflow for pancreatic cancer…

QA & dosimetryPeer-ReviewedPubMedApplied radiation and isotopes · 2026

Study of Re<sup>3+</sup> (Re<sup>3+</sup>= Er<sup>3+</sup>, Tm<sup>3+</sup>) impurity effects on thermoluminescence characteristic of magnesium sulfate nanorods.

Almasifard F, Zahedifar M.

In this research, rare earth erbium and thulium (Er 3+ and Tm3+) doped MgSO₄ nanorods (NRs) were synthesized by semi-Co-precipitation method. For assurance of MgSO₄ formation and entrance of impurity …

TherapeuticQA & dosimetryPeer-ReviewedPubMedRadiation and environmental biophysics · 2026

Dosimetry of <sup>131</sup>Cs Liquid-filled intracavitary balloon brachytherapy for enhanced treatment planning: utilizing TL dosimetry (TLD) and Monte Carlo calculation.

Kazemi A, Sardari D, Poorbaygi H, Hadadi A et al.

An intracavity balloon filled with ¹³¹Cs liquid was investigated to be used in brachytherapy, particularly for the treatment of glioblastoma multiforme (GBM), with a reference of 40-60 Gy at a depth o…

QA & dosimetryRadiation safetyCited 1×Peer-ReviewedPubMedRadiography (London, England · 2026

Critical organ dose evaluation during interventional stroke imaging: Implications for radiation safety.

Özgür E, Tunçman Kayaokay D, Özgür DS, Tünay A et al.

IntroductionNeurointerventional stroke imaging involves prolonged fluoroscopy and multiple angiographic acquisitions, potentially delivering meaningful radiation doses to radiosensitive head and neck …

QA & dosimetryPeer-ReviewedPubMedBrachytherapy · 2026

Development of a dosimetric phantom using OSLDs or TLD-100 for external audits of high-dose-rate <sup>192</sup>Ir brachytherapy sources: Preliminary results.

L Mota C, de Almeida CE, M Castro V, O da Silva A et al.

PurposeCalibration and quality control are fundamental to ensure that an accurate dose is delivered to a tumor, by HDR 192Ir radioactive sources in brachytherapy treatments. Consequently, it is essent…

Radiation safety📖 Free full textPeer-ReviewedPubMedLife (Basel, Switzerland) · 2025

Randomized Controlled Trial of Patient Positioning and Operator Radiation Exposure During Lower Extremity Catheter Angiography.

Bérczi Á, Szablics FÉ, Simon AN, Taba G et al.

Digital subtraction angiography (DSA) remains an important reference modality for evaluating chronic limb-threatening ischemia (CLTI), with left transradial access (TRA) increasingly favored for its l…

QA & dosimetryCited 1×Peer-ReviewedPubMedRadiation protection dosimetry · 2025

The reformulated unified interaction model: simulations of linear/supralinear dose reponse in LiF:Mg,Ti, dose threshold for appearance of supralinearity and deviations from linearity in the dose range 0.1-10 Gy.

Nemirovsky D, Oster L, Horowitz YS, Reshes G et al.

The Unified Interaction Model (UNIM) is reformulated to include recent advances in the understanding of the role of spatial correlations leading to localized and delocalized recombination in LiF:Mg,Ti…

TherapeuticQA & dosimetryCited 1×Peer-ReviewedPubMedZeitschrift fur medizinische Physik · 2025

Development of a TLD-100 based set up for in vivo dosimetry in Intraoperative Electron Beam Radiation Therapy (IOERT): an experimental and clinical evaluation.

Iliaskou C, Gainey M, Thomann B, Kollefrath M et al.

PurposeThis study presents an in-house developed set-up enabling the placement of multiple TLDs over the target region, for in vivo dosimetry in intraoperative electron beam radiotherapy (IOERT).Metho…

Therapeutic📖 Free full textPeer-ReviewedPubMedJournal of contemporary brachytherapy · 2025

Assessment of rectal dose with thermoluminescent in vivo dosimetry in high-dose-rate cobalt-60 intracavitary brachytherapy for cervical cancer: A two-arm cohort study using orthogonal images planning.

Mlawa OM, Ngaile JE, Chaurasia PP, Amasi AI.

PurposeHigh-dose-rate intracavitary brachytherapy delivers high radiation doses to tumors while minimizing exposure to surrounding normal cells. However, inappropriate administration can lead to radia…

QA & dosimetryRadiation safety📖 Free full textPeer-ReviewedPubMedJournal of medical physics · 2025

Radiation Dose Assessment in Diagnostic Imaging Using Thermoluminescent Dosimeter-100H Dosimeters and a RANDO Phantom: Insights from Chest, Pelvic, and Skull Examinations.

Sina S, Alizadeh S, Abbasipour S, Dalir M et al.

PurposeThis study aims to evaluate radiation doses to the skin, pelvis, and skull during routine radiographic imaging procedures.Materials and methodsEntrance skin dose (ESD) was assessed using both d…