Saxsons Lead-Lined Fume HoodHot-Lab Workstation — Configurable Across Shielding, Size, Filtration & Accessories
Saxsons own-brand lead-lined fume hood — a configurable hot-lab workstation manufactured in India in an ISO 9001 / ISO 13485 approved plant. Lead-shielded enclosure across a full tier ladder with a stainless-steel-lined work zone, counter-weighted clear acrylic sash, CE-marked motor driving an AMCA-certified centrifugal fan through a sterile-compounding-grade filter pack. Configured per site SOP — choose the size, shielding, materials, filter pack and accessory fit-out that match the workflow. AERB-compliant face-velocity certification at shipping. Sign in to view the complete configuration matrix.
Key Features
- Saxsons own-brand product — designed and manufactured in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant
- Lead-shielded enclosure with an operator-selectable shielding tier spanning routine NM, mid-activity and theranostic / high-activity workflows
- Stainless-steel-lined work zone — fully decontaminable wipe-down surfaces with coved corners; medical-grade upgrade available
- Counter-weighted clear acrylic sliding sash — effortless one-hand open / close; closes automatically on power-down
- In-cabinet fluorescent or LED work-area lamp; external control panel with on/off switch, motor switch, tube-light switch, mains indicator and 3-pin socket
All Features
- Saxsons own-brand product — designed and manufactured in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant
- Lead-shielded enclosure with an operator-selectable shielding tier spanning routine NM, mid-activity and theranostic / high-activity workflows
- Stainless-steel-lined work zone — fully decontaminable wipe-down surfaces with coved corners; medical-grade upgrade available
- Counter-weighted clear acrylic sliding sash — effortless one-hand open / close; closes automatically on power-down
- In-cabinet fluorescent or LED work-area lamp; external control panel with on/off switch, motor switch, tube-light switch, mains indicator and 3-pin socket
- CE-marked exhaust motor driving an AMCA-certified centrifugal fan; sterile-compounding-grade filter pack (premium filter train option available)
- AERB-compliant face velocity at the sash opening, verified at the time of shipping
- Accessory matrix configurable per workflow — hot-wire anemometer, negative-pressure sensor with PLC touch panel, movable body shield with lead-glass window, dose-calibrator ionisation-chamber mount, gamma-probe mount, Capintec-type lead rings, lead-bricks front-wall shielding, generator + waste compartments
- Full frame-size ladder — compact, small, standard, mid and large chassis for probe / counter benches through high-throughput hot labs
- Painted MS outer skin (standard) or full stainless outer (premium builds) — choose per cleanroom-tier expectations
- Stand with optional unshielded bottom cabinet for routine-supplies storage; stand-free variants for benchtop deployment
- Indian power connection standard; export voltage variants on request
- Documentation: site-specific build sheet, IQ / OQ / PQ protocols, factory face-velocity certificate, AERB compliance paperwork, Saxsons-branded operator manual
Technical Specifications
| Brand / build | Saxsons own-brand — manufactured in India by Saxsons Healthcare Pvt. Ltd., ISO 9001 / ISO 13485 approved plant |
| Configuration options | Multiple shielding tiers, frame sizes, work-zone / outer materials and filter/accessory packs — full ladder in the sign-in variant matrix |
| Inner material | Stainless-steel-lined work zone; medical-grade upgrade available |
| Outer material | MS painted finish (standard); full-stainless premium builds |
| Sash | Counter-weighted clear acrylic sliding sash; effortless open / close |
| Lighting | Fluorescent or LED work-zone lamp; control switch on external panel |
| Exhaust motor | CE-marked universal AC motor; on/off switch on external panel |
| Exhaust fan | AMCA-certified standard centrifugal fan; heavy-duty centrifugal blower on premium builds |
| Filter pack | Sterile-compounding-grade filter pack; premium filter train option available |
| Face velocity | AERB-compliant face velocity at the sash opening, verified at the time of shipping |
| Differential-pressure monitoring (option) | Negative-pressure sensor with PLC touch panel for live across-filter ΔP feedback; flags choke-state before face velocity drifts |
| Power connection | Indian power connection standard; export voltage variants on request |
| Stand | Frame stand standard; unshielded bottom-cabinet variant for routine supplies; stand-free benchtop variant for the compact frame |
| Compliance framework | AERB Safety Code for Nuclear Medicine Facility, ISO 9001, ISO 13485, AMCA fan certification, CE-marked motors |
| Documentation | Site build sheet, IQ / OQ / PQ protocols, factory face-velocity certificate, AERB compliance paperwork, Saxsons-branded operator manual |
Applications
One cabinet family across Tc-99m, F-18, Ga-68, Lu-177 and I-131 dispensing workflows
Tc-99m generator elution + kit dispensing
Daily Tc-99m kit reconstitution and dispensing inside a lead-shielded enclosure at the routine SPECT tier. Generator compartment variant houses the Tc-99m generator inside the cabinet; the dispensing line runs alongside without separate room shielding.
F-18 PET dose dispensing
Per-patient [18F]FDG / [18F]NaF unit-dose dispensing from a transport vial. Mid-tier shielding plus the optional Capintec-type lead rings cover the 511 keV annihilation line at typical PET unit-dose activities.
Lu-177 + Ga-68 theranostic dispensing
Heavier-tier shielding option for theranostic dispensing programmes — Lu-177 DOTATATE / PSMA-617 and Ga-68 generator elution. PLC + body-shield premium build adds operator-side dose-rate management for routine high-activity dispensing.
I-131 capsule + solution handling
I-131 capsule dispense and oral-solution decant — sterile-compounding-grade filter pack captures volatile radioiodine on the exhaust before site-stack release.
In-cabinet dose-calibrator workflow
Dose-calibrator ionisation-chamber-mount variant integrates an end-user-supplied dose calibrator inside the cabinet, with the display mounted externally. Removes a separate dispensing-bench footprint from the hot-lab fit-out.
AERB inspection-ready hot-lab fit-out
Lockable cabinet, factory face-velocity certificate, daily anemometer log (when anemometer is fitted) and the AERB compliance paperwork pack — the cabinet ships ready for first-inspection sign-off and slots into the routine inspection dossier thereafter.
Why Saxsons Lead-Lined Fume Hood?
AERB Safety Code for Nuclear Medicine Facility expects a minimum face velocity at the sash opening on dispensing fume hoods. Every Saxsons-built cabinet ships with a factory-issued face-velocity certificate at the time of shipping, and the optional hot-wire anemometer keeps the operator within spec day to day.
Routine Tc-99m kit dispensing, mid-activity F-18 / Ga-68 / Lu-177 dispensing and theranostic high-activity prep each pick a different shielding tier. One cabinet family covers the whole NM activity range — choose the shielding tier for the workflow, not for the whole department.
Designed and built in India by Saxsons Healthcare Pvt. Ltd. in an ISO 9001 / ISO 13485 approved plant. Local manufacture cuts lead times, local engineering means site-specific build sheets, and the AERB compliance paperwork lands first time because the build is documented to the AERB framework.
Catalogs & Resources
AERB + IAEA + AMCA references that anchor the lead-lined fume-hood design. Contact Saxsons Healthcare for the site-specific build sheet, IQ / OQ / PQ documentation and India pricing.
AERB — Safety Code for Nuclear Medicine Facility
Indian regulatory framework for nuclear-medicine facility licensing including dispensing fume-hood face-velocity, ventilation and shielding expectations.
IAEA Operational Guidance on Hospital Radiopharmacy
IAEA framework covering hospital-radiopharmacy hot-lab design, ventilation, fume-hood expectations and operational radiation protection.
AMCA — Air Movement and Control Association certification
AMCA fan-performance certification framework; what an AMCA-certified centrifugal-fan rating guarantees on a cabinet exhaust train.
Saxsons own-brand · Variant brochure
Request the full Saxsons Lead-Lined Fume Hood variant brochure
The detailed variant matrix, dimensions, accessories and AERB import documentation are not published on this page. Tell us who you are and a Saxsons sales engineer will email the brochure to your institutional address within one working day.
Brochure dispatch is reviewed by a sales engineer before sending — we may verify by phone.
Saxsons Lead-Lined Fume Hood
More for this product
Each card opens a focused post for a specific specialty — peer-reviewed evidence and clinical workflow, written for the persona you select.
The Saxsons-built hot-lab workstation, configured for your workflow
Contact Saxsons Healthcare Pvt. Ltd. for site-specific build sheet, shielding-tier selection, accessory matrix, IQ / OQ / PQ documentation and AERB compliance paperwork — designed and manufactured in India.